Regulatory Information
The HCPL-7560 has been approved by the following organizations:
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01.
UL
Approval under UL 1577, component recognition program up to VISO = 3750 VRMS. File E55361.
CSA
Approval under CSA Component Acceptance Notice #5, File CA 88324.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics[1]
Description
Symbol HCPL-7560 Unit
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage 300 Vrms
I - IV
for rated mains voltage 450 Vrms
I - III
for rated mains voltage 600 Vrms
I - II
Climatic Classification
40/85/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b[2]
VIORM x 1.875=VPR, 100% Production Test with tm=1 sec,
Partial discharge < 5 pC
Input to Output Test Voltage, Method a[2]
VIORM x 1.5=VPR, Type and Sample Test, tm=60 sec,
Partial discharge < 5 pC
VIORM
VPR
891
1670
VPR
1336
Vpeak
Vpeak
Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage tini = 10 sec)
VIOTM
6000
Vpeak
Safety-limiting values - maximum values allowed in the event of a failure,
also see Figure 13.
Case Temperature
Input Current[3]
Output Power[3]
TS
175
°C
IS, INPUT
400
mA
PS, OUTPUT 600
mW
Insulation Resistance at TS, VIO = 500 V
RS
>109
W
Notes:
1. Insulation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits within the
application. Surface Mount Classifications is Class A in accordance with CECC00802.
2. Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/
EN/DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
3. Refer to the following figure for dependence of PS and IS on ambient temperature.