DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

GP1F33TT Просмотр технического описания (PDF) - Sharp Electronics

Номер в каталоге
Компоненты Описание
производитель
GP1F33TT
Sharp
Sharp Electronics Sharp
GP1F33TT Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
GP1F31T/R, GP1F32T/R, GP1F33TT/RR/RT,GP1C331/331A/335
13 Output voltage/Pulse response mesuring method
Standard
transmitter
Vin Vcc
GND
5V
Input
6Mbps NRZ, duty 50%
Standard optical fiber cable
GP1F31R/GP1F32R/
GP1F33RR/GP1F33RT
Unit to be measured
Vcc GND Vout
Vcc Rso
CH1
CH2
Rsi
Oscilloscope
Standard
transmitter
Input signal
(CH1)
VOH tr
GP1F31R/GP1F32R
GP1F33RR/GP1F33RT
Output signal
(CH2)
VOL
tPLH
tf
tPHL
50% Notes 1) VCC : 5.0 ± 0.05V (Operating)
2) The probe for the oscilloscope must be more
than 1Mand less than 10pF.
3) Rsi , Rso ; Standard load resistrance
90%
( Rsi : 3.3k, R so : 2.2k)
50%
10%
14 Jitter measuring method
GP1F31T/GP1F32T/
GP1F33TT
Transmitter
Vin Vcc
GND
5V
Input
11 0 0
Input signal 3Mbps
biphase PBRS
Standard optical fiber cable
GP1F31R/GP1F32R/
GP1F33RR/GP1F33RT
Unit to be measured
Vcc GND Vout
Vcc
Rso
Rsi
CH1
CH2
Oscilloscope
Trigger : CH1
Storage mode
Sweep : AUTO/NORM
Input signal
GP1F31R output
GP1F32R output
GP1F33RR output
GP1F33RT output
tj
tj
50%
Notes 1) Rsi Rso : Strandard load resistance
( Rsi : 3.3 Rso : 2.2k)
2 ) VCC = 5.0 ± 0.05V (Operating)
3 ) Set the oscilloscope to be storage mode and
write time to 3 seconds. Do not allow the
waveform to be distorted by icreasing the
50%
brightness too much
4 ) The probe for oscilloscope must be more
than 1Mand less than 10pF.

Share Link: 