Engineering Data
● Load Current vs. Ambient Temperature
G3PF-@25B
G3PF-@25B-@TB
40
30
G3PF-225B
25
20
15
10
Individual or
close mounting
G3PF-@35B
G3PF-@35B-@TB
40
G3PF-235B
35
30
Close mounting
21
20
17
10
Individual mounting
G3PF
0
−30 −20 0
20
40
60
80 100
Ambient temperature (°C)
0
−30 −20 0
20
40
60
80 100
Ambient temperature (°C)
Note: The data above assumes that the Unit is mounted on a vertical surface. If it is mounted on a horizontal surface, reduce the load current shown above by 30%.
● One Cycle Surge Withstand Current
Non-repetitive input (For repetitive input, the figure will be less than the value for surge current withstand
indicated by the broken line.)
G3PF-@25B
G3PF-@25B-@TB
G3PF-@35B
G3PF-@35B-@TB
250
500
200
400
150
100
50
0
10 30 50 100 300 500 1,000 3,000 5,000
Energized time (ms)
300
200
100
0
10 30 50 100 300 500 1,000 3,000 5,000
Energized time (ms)
6