Absolute Maximum Ratings
Advance Information
The “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. The
device should not be operated at these limits. The parametric values defined in the Electrical Characteristics tables
are not guaranteed at the absolute maximum ratings. The “Recommended Operating Conditions” table will define the
conditions for actual device operation.
Symbol
Vs
CMIR
Parameter
Supply Voltage
Input Voltage Range
Min
0
-Vs - 0.5V
Max
12.6
+Vs + 0.5V
Unit
V
V
Recommended Operating Conditions
Symbol
Tc
Vs
Parameter
Operating Temperature Range
Supply Voltage Range
Min
Typ
Max
Unit
-40
+85
°C
5
12
V
Reliability Information
Parameter
Junction Temperature
Storage Temperature Range
Lead Temperature (Soldering, 10s)
14-Lead SOIC1
14-Lead TSSOP1
Min
-65
Note:
1. Package thermal resistance (ΘJA), JDEC standard, multi-layer test boards, still air.
Typ
128
130
ESD Protection
Package
Human Body Model (HBM)
Charge Device Model (CDM)
SOIC-14
TBD
TBD
TSSOP-14
TBD
TBD
Max
150
150
300
Unit
°C
°C
°C
°C/W
°C/W
FHP3194 Rev. 1.0.6
3