MH1M365CXJ/CNXJ-5,-6,-7
HYPER PAGE MODE 37748736-BIT ( 1048576-WORD BY 36-BIT ) DYNAMIC RAM
TIMING REQUIREMENTS (For Read, Write, Refresh, and Hyper-Page Mode Cycles)
(Ta=0 ~ 70°C, Vcc = 5V ± 10%, Vss=0V, unless otherwise noted See notes 14,15)
Symbol
Parameter
tREF
tRP
tRCD
tCRP
tRPC
tCPN
tRAD
tASR
tASC
tRAH
tCAH
tDZC
tRDD
tCDD
tT
Refresh cycle time
RAS high pulse width
Delay time, RAS low to CAS low
(Note16)
Delay time, CAS high to RAS low
Delay time, RAS high to CAS low
CAS high pulse width
Column address delay time from RAS low
(Note17)
Row address setup time before RAS low
Column address setup time before CAS low
Row address hold time after RAS low
(Note18)
Column address hold time after CAS low
Delay time, data to CAS low
(Note19)
Delay time, RAS high to data
(Note20)
Delay time, CAS high to data
(Note20)
Transition time
(Note21)
MH1M365C -5
Min
Max
16.4
30
18
37
5
0
8
13
25
0
0
10
8
8
0
13
13
1
50
Limits
MH1M365C -6
Min
Max
16.4
40
20
45
5
0
10
15
30
0
0
13
10
10
0
15
15
1
50
MH1M365C -7 Unit
Min
Max
16.4
ms
50
ns
20
50
ns
5
ns
0
ns
10
ns
15
35
ns
0
ns
0
13
ns
10
ns
10
ns
0
ns
20
ns
20
ns
1
50
ns
Note 14: The timing requirements are assumed tT =3ns.
15: VIH(min) and VIL(max) are reference levels for measuring timing of input signals.
16: tRCD(max) is specified as a reference point only. If tRCD is less than tRCD(max), access time is tRAC. If tRCD is greater than tRCD(max), access
time is controlled exclusively by tCAC or tAA.
17: tRAD(max) is specified as a reference point only. If tRAD tRAD(max) and tASC tASC(max), access time is controlled exclusively by tAA.
18: tASC(max) is specified as a reference point only. If tRCD tRCD(max) and tASC tASC(max), access time is controlled exclusively by tCAC.
19: tDZC must be satisfied.
20: Either tRDD or tCDD or tODD must be satisfied.
21: tT is measured between VIH(min) and VIL(max).
Read and Refresh Cycles
Symbol
Parameter
tRC
tRAS
tCAS
tCSH
tRSH
tRCS
tRCH
tRRH
tRAL
tCAL
Read cycle time
RAS low pulse width
CAS low pulse width
CAS hold time after RAS low
RAS hold time after CAS low
Read Setup time before CAS low
Read hold time after CAS high
Read hold time after RAS high
Column address to RAS hold time
Column address to CAS hold time
(Note 22)
(Note 22)
Note 22: Either tRCH or tRRH must be satisfied for a read cycle.
MH1M365C -5
Min
Max
90
50 10000
8 10000
40
13
0
0
10
25
13
Limits
MH1M365C -6
Min
Max
110
60 10000
10 10000
48
15
0
0
10
30
18
MH1M365C -7 Unit
Min
Max
130
ns
70
10000 ns
13
10000 ns
55
ns
20
ns
0
ns
0
ns
10
ns
35
ns
23
ns
MIT-DS-0084-1.0
MITSUBISHI
ELECTRIC
( 5 / 15 )
Oct.15.96

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]