CXA3225N
Electrical Characteristics
See the Electrical Characteristics Measurement Circuit
(Ta=25 °C, VCC=5 V)
Item
Symbol
Measurement conditions
ICCVU VHF operation asymmetrical output no input signal
Circuit current
ICCVB
ICCUU
VHF operation symmetrical output no input signal
UHF operation asymmetrical output no input signal
ICCUB UHF operation symmetrical output no input signal
CG1U VHF operation fRF=50 MHz asymmetrical output
CG2U VHF operation fRF=430 MHz asymmetrical output
CG3U UHF operation fRF=430 MHz asymmetrical output
CG4U UHF operation fRF=850 MHz asymmetrical output
Conversion gain
1
CG1B 4
VHF operation
fRF=50 MHz
symmetrical output
CG2B 4 VHF operation fRF=430 MHz symmetrical output
CG3B 4 UHF operation fRF=430 MHz symmetrical output
CG4B 4 UHF operation fRF=850 MHz symmetrical output
NF1
VHF operation fRF=50 MHz asymmetrical output
Noise figure
NF2
1, 2 NF3
VHF operation fRF=430 MHz asymmetrical output
UHF operation fRF=430 MHz asymmetrical output
NF4
UHF operation fRF=850 MHz asymmetrical output
CM1
VHF operation fD=50 MHz fUD=±12 MHz
asymmetrical output
1 % cross
CM2
modulation 1
3 CM3
VHF operation fD=430 MHz fUD=±12 MHz
asymmetrical output
UHF operation fD=430 MHz fUD=±12 MHz
asymmetrical output
CM4
UHF operation fD=850 MHz fUD=±12 MHz
asymmetrical output
Maximum
output power
Pomax
50 load, asymmetrical output
(sat)
fsw1
VHF operation fOSC=100 MHz
f from 3 seconds to 3 minutes after switch ON
Switch ON drift
fsw2
fsw3
VHF operation fOSC=470 MHz
f from 3 seconds to 3 minutes after switch ON
UHF operation fOSC=470 MHz
f from 3 seconds to 3 minutes after switch ON
fsw4
UHF operation fOSC=895 MHz
f from 3 seconds to 3 minutes after switch ON
Min. Typ. Max. Unit
35 46 55 mA
47 58 67 mA
39 50 59 mA
51 62 71 mA
20 23 26 dB
20 23 26 dB
23 26 29 dB
23 26 29 dB
29 32 35 dB
29 32 35 dB
32 35 38 dB
32 35 38 dB
12 16 dB
13 17 dB
10 13 dB
12 15 dB
99 103
dBµ
96 100
dBµ
96 100
dBµ
95 99
dBµ
7 10
dBm
±300 kHz
±600 kHz
±350 kHz
±350 kHz
1 Value measured with untuned input.
2 NF meter direct-reading value (DSB measurement).
3 Value with a desired reception signal input level of –30 dBm, an interference signal of 100 kHz/30 % AM,
and an interference signal level where S/I=46 dB measured with a spectrum analyzer.
4 Value which is measured as 420 load impedance and compensated loss by 180 resistor connected to