SPECIFICATIONS
Table 2. ABSOLUTE MAXIMUM RATINGS
Parameter
Rating
Units
Operating Supply Voltage (VP VN)
Operating Temperature Range
6.0
V
–40 to +85
°C
Storage Temperature Range
–65 to +150
°C
DC Voltage at any Channel Input
(VN 0.5) to (VP + 0.5)
V
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
Table 3. STANDARD OPERATING CONDITIONS
Parameter
Operating Temperature Range
Package Power Rating
SOT1434 Package (CM1293A02SR)
SC74 Package (CM1293A02SO)
MSOP10 Package (CM1293A04MR)
Rating
–40 to +85
225
225
400
Units
°C
mW
Table 4. ELECTRICAL OPERATING CHARACTERISTICS (Note 1)
Symbol
Parameter
Conditions
Min Typ Max
VP
Operating Supply Voltage (VPVN)
IP
Operating Supply Current
VF
Diode Forward Voltage
Top Diode
Bottom Diode
(VPVN) = 3.3 V
IF = 8 mA, TA = 25°C
3.3 5.5
8.0
0.60 0.80 0.95
0.60 0.80 0.95
ILEAK
CIN
DCIO
VESD
Channel Leakage Current
Channel Input Capacitance
Channel I/O to I/O Capacitance
ESD Protection Peak Discharge
Voltage at any Channel Input, in System
Contact Discharge per
IEC 6100042 Standard
Human Body Model, MILSTD883,
Method 3015
TA = 25°C, VP = 5 V, VN = 0 V
At 1 MHz, VP = 3.3 V, VN = 0 V, VIN = 1.65 V
TA = 25°C (Notes 2 and 4)
TA = 25°C (Notes 3 and 4)
±0.1 ±1.0
2.0
1.5
±8
±15
VCL
Channel Clamp Voltage
Positive Transients
Negative Transients
TA = 25°C, IPP = 1A, tP = 8/20 mS
(Note 4)
+9.9
–1.6
RDYN
Dynamic Resistance
TA = 25°C, IPP = 1A, tP = 8/20 mS
Positive Transients
(Note 4)
0.96
Negative Transients
0.5
1. All parameters specified at TA = –40°C to +85°C unless otherwise noted.
2. Standard IEC 6100042 with CDischarge = 150 pF, RDischarge = 330 W, VP = 3.3 V, VN grounded.
3. Human Body Model per MILSTD883, Method 3015, CDischarge = 100 pF, RDischarge = 1.5 kW, VP = 3.3 V, VN grounded.
4. These measurements performed with no external capacitor on VP.
Units
V
mA
V
mA
pF
pF
kV
V
W