SAW Components
SAW GPS filter
Data Sheet
Characteristics of Filter
Temperature range for specification:
Terminating source impedance:
Terminating load impedance:
T = –30 ˚C to +85˚C
ZS = 50 Ω
ZL = 50 Ω
Center frequency
B90371)
min. typ. max.
@ 25 ˚C
fC
— 1575.42 —
Maximum insertion attenuation
αmax
1574.42 ... 1576.42 MHz
—
0.9
1.4
B9037
1575.42 MHz
DGL2)
min./
max.
MHz
dB
Amplitude ripple (p-p)
∆α
1574.42 ... 1576.42 MHz
—
0.05
0.5
dB
Return loss (Input and Output)
1574.42 ... 1576.42 MHz
10
18
—
dB
Attenuation
α
0.3 ... 1522.42 MHz
30
35
—
dB
1628.42 ... 1750.0 MHz
30
38
—
dB
1750.0 ... 1990.0 MHz
32
39
—
dB
1990.0 ... 3000.0 MHz
30
38
—
dB
3000.0 ... 4000.0 MHz
20
33
—
dB
4000.0 ... 6000.0 MHz
17
28
—
dB
1) Values in columns min, typ and max indicate the development status of the current version.
2) Values in column DesignGoal (DGL) indicate the target performance.
Please read cautions and warnings and
important notes at the end of this document.
3 April 26, 2007