aSC7521A
SST Interface
Multi Client Mode
Sensors operate in multi-client mode for read bit timing. Reference the SST Specification Version 1.0 for details.
SST Device Commands
GetDIB() Command (0xF7)
Read the Device Identifier Block (DIB). The read length of the command is either 8 or 16 bytes. 8 bytes is the minimum number of
bytes populated by a fixed address discoverable client.
Write Data Length:
Read Data Length:
Command Code:
0x01
0x08/0x10
0xF7
Note: Un-shaded table entries are created by the host. Shaded entries are the response bytes from the aSC7521A to the host.
# Bits
Host Sending
Hex Value
# Bits
aSC7521A Sending
Hex Value
8
Target Address
0x48
8
Write Length
0x01
8
Read Length
0x10
8
GetDIB Cmd
0xF7
8
FCS
0xDC
8
DIB Byte 1
(data)
8
(data)
8
DIB Byte 15
(data)
8
DIB Byte 16
(data)
8
FCS
(data dependent)
Figure 3. GetDIB() Command (16-byte read length)
8
Target Address
0x48
8
Write Length
0x01
8
DIB Byte 1
(data)
8
(data)
8
Read Length
0x08
8
DIB Byte 7
(data)
8
GetDIB Cmd
0xF7
8
FCS
0x23
8
DIB Byte 8
(data)
8
FCS
(data dependent)
Figure 4. GetDIB() Command (8-byte read length)
Ping() Command
The Ping() command provides a safe means for software to verify that a device is responding at a particular address.
Write Data Length:
Read Data Length:
Command Code:
8
Target Address
0x48
0x00
0x00
none
8
Write Length
0x00
8
Read Length
0x00
8
FCS
0xD7
© Andigilog, Inc. 2006
Figure 5. Example of Ping()