Technical Reference Notes
APC18T12 Series
Electrical Specifications (continued)
SAFETY AGENCY / MATERIAL RATING / ISOLATION
Parameter
Safety Approval
Device
All
UL/cUL 60950, Flamability and Temperature Rise
Material Flammability Rating
All
Input to Output Insulation Type
All
UL94V-0
Non-Isolated
Figure 1. Measure input reflected-ripple current with a simulated source inductance L1
of 1 uH. Capacitor C1 offsets possible battery impedance. Measure current as shown
above.
Vo(+)
Vo(-)
COPPER STRIP
C1 C2 C3
SCOPE
RESISTIVE
LOAD
Figure 2. Use C1 = 0.1µF @50V X7R ceramic capacitor (connected an inch away
from the output terminals of the UUT), C2 = 10µF @ 25V tantalum capacitor (2 inches
away from the output terminals of the UUT), C3 = 2x 150uF Polymer cap. Scope
measurement should be made using a BNC socket, positioned 3 inches away from
output terminals of the converter.
MODEL: APC18T12 SERIES
NOVEMBER 4, 2004 - REVISION 00
SHEET 5 OF 10