FSF055D, FSF055R
Source to Drain Diode Specifications
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
TYP
Forward Voltage
VSD
ISD = 25A
0.6
-
Reverse Recovery Time
trr
ISD = 25A, dISD/dt = 100A/µs
-
-
Electrical Specifications up to 100K RAD TC = 25oC, Unless Otherwise Specified
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
Drain to Source Breakdown Volts (Note 3)
BVDSS VGS = 0, ID = 1mA
60
Gate to Source Threshold Volts (Note 3)
VGS(TH) VGS = VDS, ID = 1mA
1.5
Gate to Body Leakage
(Notes 2, 3)
IGSS
VGS = ±20V, VDS = 0V
-
Zero Gate Leakage
(Note 3)
IDSS
VGS = 0, VDS = 48V
-
Drain to Source On-State Volts (Notes 1, 3)
VDS(ON) VGS = 12V, ID = 25A
-
Drain to Source On Resistance (Notes 1, 3)
rDS(ON)12 VGS = 12V, ID = 25A
-
NOTES:
1. Pulse test, 300µs Max.
2. Absolute value.
3. Insitu Gamma bias must be sampled for both VGS = 12V, VDS = 0V and VGS = 0V, VDS = 80% BVDSS.
Single Event Effects (SEB, SEGR) (Note 4)
MAX
1.8
290
MAX
-
4.0
100
25
0.525
0.020
UNITS
V
ns
UNITS
V
V
nA
µA
V
TEST
SYMBOL
ENVIRONMENT (NOTE 5)
ION
SPECIES
TYPICAL LET
(MeV/mg/cm)
TYPICAL
RANGE (µ)
APPLIED
VGS BIAS
(V)
Single Event Effects Safe Operating
SEESOA
Ni
26
43
-20
Area
Br
37
36
-10
Br
37
36
-15
Br
37
36
-20
I
60
31
0
I
60
31
-5
I
60
31
-10
I
60
31
-15
I
60
31
-20
NOTES:
4. Testing conducted at Brookhaven National Labs; sponsored by Naval Surface Warfare Center (NSWC), Crane, IN.
5. Fluence = 1E5 ions/cm2 (typical), T = 25oC.
6. Does not exhibit Single Event Burnout (SEB) or Single Event Gate Rupture (SEGR).
(NOTE 6)
MAXIMUM
VDS BIAS (V)
60
60
48
36
60
48
36
24
12
Typical Performance Curves Unless Otherwise Specified
1-
LET = 26MeV/mg/cm2, RANGE = 43µ
2-
LET = 37MeV/mg/cm2, RANGE = 36µ
3-
LET = 60MeV/mg/cm2, RANGE = 31µ
70
FLUENCE = 1E5 IONS/cm2 (TYPICAL)
60
50
1
40
30
2
20
3
10
TEMP = 25oC
0
0
-5
-10
-15
-20
-25
VGS (V)
FIGURE 1. SINGLE EVENT EFFECTS SAFE OPERATING AREA
1E-3
1E-4
1E-5
1E-6
ILM = 10A
30A
100A
300A
1E-7
10
30
100
300
DRAIN SUPPLY (V)
1000
FIGURE 2. DRAIN INDUCTANCE REQUIRED TO LIMIT
GAMMA DOT CURRENT TO IAS