AC ELECTRICAL CHARACTERISTICS
TA = 25°C V+ = +5.0V, V- = -5.0V, GND = 0.0V unless otherwise specified
Parameter
4211/4212/4213(PC) 4211/4212/4213(DC) 4211/4212/4213(SC)
Symbol Min Typ Max Min Typ Max Min Typ Max Unit
Turn On
Delay time
tON
60 130
60 130
60 130 ns
Test Conditions
(Note 2)
Turn Off
Delay time
tOFF
60 130
60 130
60 130 ns
(Note 2)
Charge Injection
Off Isolation
Crosstalk
QINJ
0.2 1.0
75
90
0.2 1.0
75
90
0.2 1.0 pC
75
dB
90
dB
(Note 3) (Note 4)
At f = 100KHz, (Note 5)
At f = 100KHz, (Note 6)
Total Harmonic
Distortion
Com/Out
Off Capacitance
THD
COM(OFF)
OUT(OFF)
0.05
0.01
3.0
0.05
0.01
3.0
0.05
%
RL = 10K
0.01
RL = 100K
3.0
pF
Channel On
Capacitance
CDS (ON)
5.7
5.7
5.7
pF
Pin to Pin
Capacitance
CPP
0.5
0.6
0.25
pF
DC ELECTRICAL CHARACTERISTICS
TA = 25°C V+ = +5.0V, V- = GND = 0.0V unless otherwise specified
Parameter
Symbol
4211/4212/4213 (PC,SC)
Min
Typ Max
4211/4212/4213 (DC)
Min
Typ
Max Unit
Analog Signal Range
VA
0.0
+5.0
0.0
+5.0 V
Test Conditions
On - Resistance
RON
195
280
250
365
195
280
VA = 0V IA = 1mA
-40°C to +85°C
270
390
-55°C to +125°C
Change of On-Resistance
from -VS to +VS
Change of On-Resistance
with Temperature
RON
RON/T
20
0.43
20
%
0.43
%/°C
RON Match
Between Switches
2
2
%
Off Com Leakage
Current
ICOML
50
100
500
50
100
4000
pA VCOM = +/-4.0V,VOUT = -/+4.0V
pA -40°C to +85°C
pA -55°C to +125°C
Off Out Leakage
Current
IOUTL
50
100
500
50
100
4000
pA VOUT = +/-4.0V,VCOM = -/+4.0V
pA -40°C to +85°C
pA -55°C to +125°C
On Channel
Leakage Current
ID(ON)
50
100
500
50
100
4000
pA
pA -40°C to +85°C
pA -55°C to +125°C
Input High Voltage
Input Low Voltage
Input High or
Input Low Current
Supply Current
VIH
4.0
4.0
Logic "1"
VIL
0.8
0.8 V
Logic "0"
IIH
IIL
10
10 nA
ISUPPLY
0.01
1
0.01
1 µA
Notes: 1. Voltage on any terminal must be less than (V+) + 0.3V and greater than (V-) - 0.3V, at all times including before power is applied and V+ =V- = 0.0V. Vsupply
power supply needs to be sequenced on first on power turn-on and sequenced off last during power turn-off. 2. See Switching Time Test Circuit. Break-before-make time is
not guaranteed. Turn on and turn off time may overlap. 3. Guaranteed by design. 4. See Charge Injection Test Circuit 5. See Off Isolation Test Circuit 6. See Crosstalk
Test Circuit. 7. See switching time test circuit.
ALD4211/ALD4212
Advanced Linear Devices
3
ALD4213

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]