DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ADXL322JCP-REEL Просмотр технического описания (PDF) - Analog Devices

Номер в каталоге
Компоненты Описание
производитель
ADXL322JCP-REEL
ADI
Analog Devices ADI
ADXL322JCP-REEL Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ADXL322
SPECIFICATIONS
TA = 25°C, VS = 3 V, CX = CY = 0.1 μF, Acceleration = 0 g, unless otherwise noted1.
Table 1.
Parameter
SENSOR INPUT
Measurement Range
Nonlinearity
Package Alignment Error
Alignment Error
Cross-Axis Sensitivity
SENSITIVITY (RATIOMETRIC)2
Sensitivity at XOUT, YOUT
Sensitivity Change due to Temperature3
ZERO g BIAS LEVEL (RATIOMETRIC)
0 g Voltage at XOUT, YOUT
Initial 0 g Bias Deviation from Ideal
0 g Offset Vs. Temperature
NOISE PERFORMANCE
Noise Density
FREQUENCY RESPONSE4
CX, CY Range5
RFILT Tolerance
Sensor Resonant Frequency
SELF-TEST6
T
Logic Input Low
Logic Input High
ST Input Resistance to Ground
Output Change at XOUT, YOUT
OUTPUT AMPLIFIER
Output Swing Low
Output Swing High
POWER SUPPLY
Operating Voltage Range
Quiescent Supply Current
Turn-On Time7
TEMPERATURE
Operating Temperature Range
Conditions
Each axis
% of full scale
X sensor to Y sensor
Each axis
VS = 3 V
VS = 3 V
Each axis
VS = 3 V
at 25°C
Self-test 0 to 1
No load
No load
Min Typ
Max
±2
±0.2
±1
±0.1
±2
378 420
462
0.01
1.3
1.5
1.7
±50
<±0.5
220
0.002
10
32 ± 15%
5.5
0.6
2.4
50
125
0.2
2.7
2.4
6
0.45
20
−20
70
Unit
g
%
Degrees
Degrees
%
mV/g
%/°C
V
mg
mg/°C
μg/√Hz rms
μF
kHz
V
V
mV
V
V
V
mA
ms
°C
1 All minimum and maximum specifications are guaranteed. Typical specifications are not guaranteed.
2 Sensitivity is essentially ratiometric to VS. For VS = 2.7 V to 3.3 V, sensitivity is 138 mV/V/g to 142 mV/V/g typical.
3 Defined as the output change from ambient-to-maximum temperature or ambient-to-minimum temperature.
4 Actual frequency response controlled by user-supplied external capacitor (CX, CY).
5 Bandwidth = 1/(2 × π × 32 kΩ × C). For CX, CY = 0.002 μF, bandwidth = 2500 Hz. For CX, CY = 10 μF, bandwidth = 0.5 Hz. Minimum/maximum values are not tested.
6 Self-test response changes cubically with VS.
7 Larger values of CX, CY increase turn-on time. Turn-on time is approximately 160 × CX or CY + 4 ms, where CX, CY are in μF.
Rev. 0 | Page 3 of 16