DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ADXL206(Rev0) Просмотр технического описания (PDF) - Analog Devices

Номер в каталоге
Компоненты Описание
производитель
ADXL206 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ADXL206
SPECIFICATIONS
TA = −40°C to +175°C, VS = 5 V, CX = 0.1 μF, acceleration = 0 g, unless otherwise noted.1
Table 1.
Parameter
SENSOR INPUT
Measurement Range2
Nonlinearity
Package Alignment Error
Alignment Error
Cross-Axis Sensitivity
SENSITIVITY (RATIOMETRIC)3
Sensitivity at XOUT, YOUT
Sensitivity Change Due to Temperature4
ZERO g BIAS LEVEL (RATIOMETRIC)
0 g Voltage at XOUT, YOUT
0 g Bias Repeatability
NOISE PERFORMANCE
Noise Density
FREQUENCY RESPONSE5
CX, CY Range6
RFILT Tolerance
Sensor Resonant Frequency
SELF-TEST7
Logic Input Low
Logic Input High
ST Input Resistance to Ground
Output Change at XOUT, YOUT
OUTPUT AMPLIFIER
Output Swing Low
Output Swing High
LIFESPAN
Usable Life Expectancy
POWER SUPPLY
Operating Voltage Range
Supply Current
Turn-On Time8
Test Conditions/Comments
Each axis
X sensor to Y sensor
VS = 5 V
VS = 5 V
VS = 5 V, TA = 25°C
−40°C ≤ TA ≤ +175°C
VS = 5 V, TA = 25°C
ST pin Logic 0 to Logic 1
No load
TA = 175°C
Min
±5
296
0.002
24
4
30
150
0.05
1000
4.75
Typ
Max
±0.2
±1
±0.1
±1.5
312
328
±0.3
2.5 ± 0.025
±10
110
10
32
40
5.5
1
50
250
350
0.2
4.5
5.25
0.7
1.5
20
Unit
g
% FS
Degrees
Degrees
%
mV/g
%
V
mg
μg/√Hz rms
μF
kHz
V
V
mV
V
V
Hours
V
mA
ms
1 Minimum and maximum specifications are guaranteed. Typical specifications are not guaranteed.
2 Guaranteed by measurement of initial offset and sensitivity.
3 Sensitivity is essentially ratiometric to VS. For VS = 4.75 V to 5.25 V, sensitivity is 186 mV/V/g to 215 mV/V/g.
4 Defined as the output change from ambient temperature to maximum temperature or from ambient temperature to minimum temperature.
5 Actual frequency response controlled by user-supplied external capacitors (CX, CY).
6 Bandwidth = 1/(2 × π × 32 kΩ × C). For CX, CY = 0.002 μF, bandwidth = 2500 Hz. For CX, CY = 10 μF, bandwidth = 0.5 Hz. Minimum/maximum values are not tested.
7 Self-test response changes cubically with VS.
8 Larger values of CX, CY increase turn-on time. Turn-on time is approximately 160 × CX or CY + 4 ms, where CX and CY are in microfarads (μF).
Rev. 0 | Page 3 of 12