ACS716
120 kHz Bandwidth, High Voltage Isolation
Current Sensor with Integrated Overcurrent Detection
COMMON OPERATING CHARACTERISTICS (continued) Valid at TA = –40°C to 125°C, VCC = 3.3 V, unless otherwise specified
Characteristic
Symbol
Test Conditions
Min.
Typ.
Max.
OVERCURRENT CHARACTERISTICS (continued)
Units
Fault Enable (FAULT_EN Pin) Input High
Voltage Threshold
VIH
0.8 × VCC
V
Fault Enable (FAULT_EN Pin) Input
Resistance
RFEI
1
MΩ
Fault Enable (FAULT_EN Pin) Delay7
Set FAULT_EN to low, VOC = 0.25 × VCC ,
COC = 0 F; then run a DC IP exceeding the
tFED
corresponding overcurrent threshold; then
reset FAULT_EN from low to high and
measure the delay from the rising edge of
FAULT_EN to the falling edge of ¯F¯¯A¯U¯¯L¯¯T¯
15
μs
Fault Enable (FAULT_EN Pin) Delay
(Non-Latching versions)8
Set FAULT_EN to low, VOC = 0.25 × VCC ,
COC = 0 F; then run a DC IP exceeding the
tFED(NL)
corresponding overcurrent threshold; then
reset FAULT_EN from low to high and
measure the delay from the rising edge of
FAULT_EN to the falling edge of ¯F¯¯A¯U¯¯L¯¯T¯
150
ns
Overcurrent Fault Response Time
Undercurrent Fault Response Time
(Non-Latching versions)
Overcurrent Fault Reset Delay
Overcurrent Fault Reset Hold Time
FAULT_EN set to high for a minimum
of 20 μs before the overcurrent event;
switchpoint set at VOC = 0.25 × VCC ;
tOC
apply a current step to IP with amplitude
equal to 1.5 x VOC/ Sens;
delay from IP exceeding overcurrent
fault threshold to V ¯F¯¯A¯U¯¯L¯¯T¯ < 0.4 V, without
external COC capacitor
FAULT_EN set to high for a minimum
of 20 μs before the undercurrent event;
tUC
switchpoint set at VOC = 0.25 × VCC ; delay
from IP falling below the overcurrent fault
threshold to V ¯F¯¯A¯U¯¯L¯¯T¯ > 0.8 × VCC, without
external COC capacitor, RPU = 330 kΩ
tOCR
Time from VFAULTEN < VIL to
VFAULT > 0.8 × VCC , RPU = 330 kΩ
tOCH
Time from VFAULTEN pin < VIL to reset of
fault latch; see Functional Block Diagram
2
μs
3
μs
500
ns
250
ns
Overcurrent Input Pin Resistance
ROC
VOLTAGE REFERENCE CHARACTERISTICS
TA = 25°C, VOC pin to GND
2
MΩ
Voltage Reference Output
VZCR
TA = 25 °C
(Not a highly accurate reference)
0.48 x VCC 0.5 × VCC 0.52 x VCC V
Voltage Reference Output Load Current
Source current
IZCR
Sink current
3
mA
50
μA
Voltage Reference Output Drift
VZCR
±10
mV
1RF(INT) forms an RC circuit via the FILTER pin.
2This parameter can drift by as much as 0.8% over the lifetime of this product.
3This parameter can drift by as much as 1% over the lifetime of this product.
4See page 8 on how to set overcurrent fault switchpoint.
5Switchpoint can be lower at the expense of switchpoint accuracy.
6This error specification does not include the effect of noise. See the INCOMP specification in order to factor in the additional influence of noise on the
fault switchpoint.
7Fault Enable Delay is designed to avoid false tripping of an Overcurrent (OC) fault at power-up. A 15 μs (typical) delay will always be needed, every
time FAULT_EN is raised from low to high, before the device is ready for responding to any overcurrent event.
8During power-up, this delay is 15 μs in order to avoid false tripping of an Overcurrent (OC) fault.
Allegro MicroSystems, LLC
7
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com