Номер в каталоге
Компоненты Описание
производитель
ACPL-W314-000E
AVAGO
Avago Technologies AVAGO
ACPL-W314-000E Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
The ACPL-P314/W314 is approved by the following organizations:
IEC/EN/DIN EN 60747-5-2 (Option 060 only)
Approval under:
IEC 60747-5-5:2007
UL
Approval under UL 1577 component recognition
program up to VISO = 3750 VRMS for the ACPL-P314 and
VISO = 5000 VRMS for the ACPL-W314, File E55361.
CSA
Approval under CSA Component Acceptance Notice #5,
File CA 88324.
Table 1. IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics* (ACPL-P314/W314 Option 060)
Description
Symbol
ACPL-W14
ACPL-P314
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage 150 Vrms
for rated mains voltage 300 Vrms
for rated mains voltage 450 Vrms
for rated mains voltage 600 Vrms
for rated mains voltage 1000 Vrms
I-IV
I-IV
I-IV
I-IV
I-IV
I-III
I-IV
I-III
I-III
Climatic Classification
55/100/21
55/100/21
Pollution Degree (DIN VDE 0110/1.89)
2
2
Maximum Working Insulation Voltage
VIORM
1140
891
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec
VPR
Partial Discharge < 5 pC,
2137
1670
Units
V peak
V peak
Input to Output Test Voltage, Method a*
VIORM x 1.6 = VPR, Type and sample test, tm = 10 sec,
Partial Discharge < 5 pC
VPR
1824
1426
V peak
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 60 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure)
Case Temperature
Input Current**
Output Power **
Insulation Resistance at TS, VIO = 500 V
VIOTM
8000
TS
IS,INPUT
PS,OUTPUT
RS
175
230
600
109
6000
175
230
600
109
V peak
°C
mA
mW
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog,
800
under Product Safety Regulations section, (IEC/EN/DIN EN 60747-5-2) for a detailed description
of Method a and Method b partial discharge test profiles.
700
** Refer to the following figure for dependence of PS and IS on ambient temperature.
600
500
400
PS (mW)
IS (mA)
300
200
100
0
0 25 50 75 100 125 150 175 200
TS – CASE TEMPERATURE – °C
4