Table 3. Insulation and Safety Related Specifications
Parameter
Symbol Value Unit
Minimum External Air Gap
(External Clearance)
L(101)
8.0
mm
Minimum External
L(102)
8.0
mm
Tracking (External Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
0.5
mm
Tracking Resistance
CTI
(Comparative Tracking Index)
Isolation Group
> 175 V
IIIa
Conditions
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Through insulation distance, conductor to conductor,
usually the direct distance between the photoemitter
and photodetector inside the optocoupler cavity
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Table 4. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics [1]
Description
Symbol
Value
Units
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
I-IV
for rated mains voltage ≤ 300 Vrms
I-IV
for rated mains voltage ≤ 450 V rms
I-IV
for rated mains voltage ≤ 600 Vrms
I-IV
for rated mains voltage ≤ 1000 Vrms
I-III
Climatic Classification
55/105/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage (Pending Qualification)
VIORM
1230
Vpeak
Input to Output Test Voltage, Method b
VPR
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec, Partial Discharge < 5 pC
2306
Vpeak
Input to Output Test Voltage, Method a
VPR
VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec, Partial Discharge < 5 pC
1968
Vpeak
Highest Allowable Overvoltage (Transient Overvoltage, tini = 60 sec)
VIOTM
8000
Vpeak
Safety-limiting values (Maximum values allowed in the event of a failure)
Case Temperature
Input Current [2]
Output Power [2]
TS
175
°C
IS,INPUT
230
mA
PS,OUTPUT
600
mW
Insulation Resistance at TS, VIO = 500 V
RS
≥ 109
Notes:
1. Insulation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits within the
application.