Table 8. Timing Specifications
Unless otherwise noted, TA = -40° C to +105° C, VDD1 = 4.5 V to 5.5 V, VDD2 = 3 V to 5.5 V.
Parameter
Symbol Min. Typ. Max. Units Test Conditions/Notes
Fig.
Modulator Clock Output Frequency
fMCLK
9
10 11 MHz Clock duty cycle 40% to 60% 13
Data Access Time After MCLK Rising Edge tA
40 ns
CL = 15 pF
4
Data Hold Time After MCLK Rising Edge tH
10
ns
CL = 15 pF
4
MCLK
tA
tH
MDAT
Figure 4. Data timing.
Table 9. Package Characteristics
Parameter
Symbol Min. Typ. Max. Unit Test Condition
Note
Input-Output Momentary Withstand
Voltage
VISO
5000
Vrms RH < 50%, t = 1 min; TA = 25° C 1, 2
Input-Output Resistance
RI-O
1012 1013
VI-O = 500 VDC
3
1011
TA = 100° C
3
Input-Output Capacitance
CI-O
1.4
pF
f = 1 MHz
3
Notes:
1. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 6000 Vrms for 1 second (leakage detection
current limit, II-O ≤ 5 µA). This test is performed before the 100% production test for partial discharge (method b) shown in IEC/EN/DIN EN 60747-
5-5 Insulation Characteristic Table.
2. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating, refer to the IEC/EN/DIN EN 60747-5-5 insulation characteristics table and your equipment level
safety specification.
3. This is a two-terminal measurement: pins 1–4 are shorted together and pins 5–8 are shorted together.
8