Table 1. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics*
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage 150 Vrms
for rated mains voltage 300 Vrms
for rated mains voltage 450 Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b**
VIORM x 1.875=VPR, 100% Production Test with tm=1 sec,
Partial discharge < 5 pC
Input to Output Test Voltage, Method a**
VIORM x 1.5=VPR, Type and Sample Test, tm=60 sec, Partial discharge < 5 pC
Highest Allowable Overvoltage (Transient Overvoltage tini = 10 sec)
Safety-limiting values – maximum values allowed in the event of a failure,
also see Figure 2.
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
Symbol
VIORM
VPR
VPR
VIOTM
TS
IS, INPUT
PS, OUTPUT
RIO
ACPL-772L ACPL-072L
Option 060 Option 060 Units
I – IV
I – IV
I – III
55/105/21
2
630
1181
I – IV
I – III
55/105/21
2
560
1050
Vpeak
Vpeak
945
6000
175
230
600
>109
840
4000
150
150
600
>109
Vpeak
Vpeak
°C
mA
mW
W
* Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
Surface mount classification is class A in accordance with CECCOO802.
** Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section IEC/EN/
DIN EN 60747-5-2, for a detailed description of Method a and Method b partial discharge test profiles.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured
by means of protective circuits.
Note: The surface mount classification is Class A in accordance with CECC 00802.
Table 2. Insulation and Safety Related Specifications
Parameter
Minimum External
Air Gap (Clearance)
Minimum External
Tracking (Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
Symbol
L(101)
L(102)
CTI
Value
ACPL-
772L ACPL-072L
7.1
4.9
7.4
4.8
0.08
0.08
>175
>175
Units
mm
mm
mm
V
Conditions
Measured from input terminals to output termi-
nals, shortest distance through air.
Measured from input terminals to output termi-
nals, shortest distance path along body.
Through insulation distance conductor to con-
ductor, usually the straight line distance thickness
between the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
IIIa
IIIa
Material Group (DIN VDE 0110, 1/89, Table 1)
All Avago Technologies data sheets report the creepage and clearance inherent to the optocoupler component itself. These dimensions are needed as
a starting point for the equipment designer when determining the circuit insulation requirements. However, once mounted on a printed circuit board,
minimum creepage and clearance requirements must be met as specified for individual equipment standards. For creepage, the shortest distance
path along the surface of a printed circuit board between the solder fillets of the input and output leads must be considered.
There are recommended techniques such as grooves and ribs which may be used on a printed circuit board to achieve desired creepage and clearances.
Creepage and clearance distances will also change depending on factors such as pollution degree and insulation level.