DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACPL-024L-560E Просмотр технического описания (PDF) - Avago Technologies

Номер в каталоге
Компоненты Описание
производитель
ACPL-024L-560E
AVAGO
Avago Technologies AVAGO
ACPL-024L-560E Datasheet PDF : 11 Pages
1 2 3 4 5 6 7 8 9 10
Insulation and Safety Related Specifications
Parameter
Minimum External Air Gap
(Clearance)
Minimum External
Tracking (Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Symbol
L(101)
L(102)
ACPL-M21L
5
5
0.08
Tracking Resistance
CTI
175
(Comparative Tracking Index)
Isolation Group
IIIa
ACPL-024L
ACPL-021L
4.9
4.8
0.08
175
IIIa
Units
mm
mm
mm
Volts
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance conductor to
conductor, usually the straight line distance
thickness between the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
IEC/EN 60747-5-5 Insulation Characteristics* (Option 060)
Characteristic
Description
Symbol
ACPL-M21L/
024L/021L Unit
Installation classification per DIN VDE 0110/39, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
for rated mains voltage ≤ 1000 Vrms
I – IV
I – III
I – II
Climatic Classification
55/105/21
Pollution Degree (DIN VDE 0110/39)
2
Maximum Working Insulation Voltage
VIORM
567
Vpeak
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test
with tm = 1 sec, Partial discharge < 5 pC
VPR
1063
Vpeak
Input to Output Test Voltage, Method a*
VIORM x 1.6 = VPR, Type and Sample Test,
tm = 10 sec, Partial discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage tini = 60 sec)
VPR
VIOTM
896
6000
Vpeak
Vpeak
Safety-limiting values – maximum values allowed in
the event of a failure.
Case Temperature
TS
150
°C
Input Current**
IS, INPUT
150
mA
Output Power**
PS, OUTPUT
600
mW
Insulation Resistance at TS, VIO = 500 V
RS
>109
W
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section,
(IEC/EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test profiles.
** Refer to the following figure for dependence of PS and IS on ambient temperature.