A1180, A1181,
A1182, and A1183
Sensitive Two-Wire Field-Programmable
Chopper-Stabilized Unipolar Hall Effect Switches
ELECTRICAL CHARACTERISTICS over the operating voltage and temperature range, unless otherwise specified
Characteristic
Symbol
Test Conditions
Min.
Typ.
Max. Units
Supply Voltage1
Supply Current2
Supply Zener Clamp Voltage
Supply Zener Clamp Current
VCC
ICC(L)
ICC(H)
VZ(supply)
Device powered on
B >BOP for A1180; B <BRP for A1181
B >BOP for A1182; B <BRP for A1183
B >BOP for A1181, A1183
B <BRP for A1180, A1182
ICC = ICC(L)(max) + 3 mA; TA = 25°C
IZ(supply) VZ(supply) = 28 V
3.5
–
24
V
2
–
5
mA
5
–
6.9
mA
12
–
17
mA
28
–
40
V
–
–
ICC(L)(max)
mA
+ 3 mA
Reverse Supply Current
Output Slew Rate3
IRCC
VRCC = –18 V
–
No bypass capacitor; capacitance of the
di/dt oscilloscope performing the measurement
–
= 20 pF
–
–1.6
mA
36
–
mA/μs
Chopping Frequency
fC
–
200
–
kHz
Power-On Time4
ton
After factory trimming; with and without
bypass capacitor (CBYP = 0.01 μF)
–
–
25
μs
Power-On State5,6
POS
ton ≤ ton(max); VCC slew rate ≥ 25 mV/μs
–
HIGH
–
–
1VCC represents the generated voltage between the VCC pin and the GND pin.
2Relative values of B use the algebraic convention, where positive values indicate south magnetic polarity, and negative values indicate north magnetic
polarity; therefore greater B values indicate a stronger south polarity field (or a weaker north polarity field, if present).
3Measured without bypass capacitor between VCC and GND. Use of a bypass capacitor results in slower current change.
4Measured with and without bypass capacitor of 0.01 μF. Adding a larger bypass capacitor causes longer Power-On Time.
5POS is defined as true only with a VCC slew rate of 25 mV / μs or greater. Operation with a VCC slew rate less than 25 mV / μs can permanently harm
device performance.
6POS is undefined for t > ton or BRP < B < BOP .
MAGNETIC CHARACTERISTICS1 over the operating voltage and temperature range, unless otherwise specified
Characteristic
Programmable Operate Point Range
Initial Operate Point Range
Switchpoint Step Size2
Number of Programming Bits
Symbol
BOPrange
BOPinit
BRES
–
Test Conditions
ICC = ICC(H) for A1180 and A1182
ICC = ICC(L) for A1181 and A1183
VCC = 12 V
VCC = 5 V, TA = 25°C
Switchpoint setting
Programming locking
Min.
Typ.
Max. Units
60
–
200
G
–
33
60
G
4
8
12
G
–
5
–
Bit
–
1
–
Bit
Temperature Drift of BOP
∆BOP
–
–
±20
G
Hysteresis
BHYS BHYS = BOP – BRP
5
15
30
G
1Relative values of B use the algebraic convention, where positive values indicate south magnetic polarity, and negative values indicate north magnetic
polarity; therefore greater B values indicate a stronger south polarity field (or a weaker north polarity field, if present).
2The range of values specified for BRES is a maximum, derived from the cumulative programming bit errors.