DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

IEC61000-4-5 Просмотр технического описания (PDF) - Unspecified

Номер в каталоге
Компоненты Описание
производитель
IEC61000-4-5 Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
Panel Mount Power Supply 5V 35W 1Phase
SAFETY STANDARDS /EMC
SAFETY STANDARD
CCC
SIQ to EN60950-1,
UL/cUL Recognize to UL 60950-1 asd CSA C22.2 no. 60950-1
CE EMC and Low Voltage directive
CB test certificate and report to IEC60950-1
EMI
FCC Title 47, Class B / EN55022, CISPR22, CLASS B
EMS
EN 61000-4-2 1)
LEVEL 4 Criteria A
Electrostatic Discharge Standard
Air Discharge
: 15 KV
(ESD)
Contact discharge : 8 KV
EN 61000-4-3 1)
LEVEL 3 Criteria A
Radiate Field Immunity
80MHz - 1GHz / 10V/M with 1kHz tone / 80% modulation.
EN 61000-4-4 1)
Fast transients (Burst Immunity)
LEVEL 3 Criteria A
2 KV4)
IEC 61000-4-5 1)
Surge voltage Immunity
LEVEL 3 Criteria A
Common Mode : 2 KV3)
Differential Mode : 1 KV4)
EN 61000-4-6 1)
LEVEL 3 Criteria A
Conducted Immunity
150KHz - 80MHz / 10Vrms.
EN 61000-4-8 1)
LEVEL 3 Criteria A
Power frequency magnetic field
10A/Meter
EN 61000-4-11 2)
Voltage dips
Input 100% dip 1 cycle, Main Buffering > 20ms, Self Recoverable
IEC 61000-4-12 1)
Low Energy Pulse Test (Ring Wave)
LEVEL 3 Criteria A
Common Mode : 2 KV3)
Differential Mode : 1 KV4)
Galvanic Isolation :
Input / output
type test/routine test :
3.0 KVac/
Input / PE
type test/routine test :
1.5 KVac/
output / PE
type test/routine test :
500Vac/
1) Criterion A: Normal operating behavior within the defined limits.
2) Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
3) Symmetrical: Conductor to conductor.
4) Asymmetrical: Conductor to ground.
Delta RoHS Compliant
Restriction of the usage of hazardous substances
The European directive 2002/95/EC limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium,
chrome6+, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHs is the abbreviation
for “Restriction of the use of certain hazardous substances in electrical and electronic equipment”. All items in the catalog conform to this
standard.
PFC Norm EN 61000-3-2
Line Current harmonic content
Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial
environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some
technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs, Frequently, the
user does not profit form fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a
specific application.
www.DeltaPSU.com
10