ZXCM209
ZXCM210
ELECTRICAL CHARACTERISTICS ZXCM209
TEST CONDITIONS (unless otherwise stated) V = full range, T = -55°C to +125°C
CC
A
SYMBOL PARAMETER
CONDITIONS
LIMITS
UNITS
MIN TYP MAX
VOL
VOH
Reset Output Voltage
Low
Reset Output Voltage
High
VCC>1V, IOL=100µA (0 to 85°C)
VCC>1.2V, IOL=200µA
VTH>VCC>2.5V, IOL=2.7mA
VCC>VTHmax, IOH=1mA
0.8Vcc
0.3
V
0.3
V
0.4
V
V
ELECTRICAL CHARACTERISTICS ZXCM210
TEST CONDITIONS (unless otherwise stated) VCC = full range, TA = -55°C to +125°C
SYMBOL PARAMETER
CONDITIONS
LIMITS
UNITS
MIN TYP MAX
VOL
VOH
Reset Output Voltage
Low
Reset Output Voltage
High
VCC>VTHmax, IOL=2mA
VCC>VTHmax, IOL=2.7mA
VCC>1.5V, IOH=150µA
VCC>VTH>2.5V, IOH=1mA
0.8Vcc
0.8Vcc
0.3
V
0.4
V
V
V
Note: Device testing is performed at TA=25°C. Device thermal performance is guaranteed by design
TYPICAL CHARACTERISTICS
ISSUE 3 - FEBRUARY 2001
3