DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

PFM19030 Просмотр технического описания (PDF) - Cree, Inc

Номер в каталоге
Компоненты Описание
производитель
PFM19030 Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Electrical Specification
PFM19030
Parameter
1 Operating Frequency
Limits
Min Typ Max
1930
-
1990
Units
MHz
Comments
2 Gain
27.0
3
Gain Compression at
Pout =30 Watts
-
4
Gain Flatness over any
30 MHz bandwidth
-
Deviation from Linear
5 Phase over any 30
-
MHz bandwidth
6 Group Delay
-
7
ACPR with IS95A
CDMA Pave = 5 W
-45
8 Efficiency under IS-95
Protocol, Pave = 5 W
18
9
Efficiency @ 30W
CW Output
10
DC Drain Supply
Voltage
24
Operating
11 Temperature Range
-40
(base temperature)
12
Gain Variation versus
Temperature
-
13
Output Mismatch
Stress
-
14 Stability
-60
15 Theta jc (channel)
-
Quiescent Currents
16 a) Q1
b) Q2
Sense FET Current/RF
FET Current Ratio
17
a) Stg 1 Sense
b) Stg 2 Sense
ESD Protection
18
a) Human Body Model
b) Machine Model
29.0 31.5
0.8
1.5
± 0.2 ± 0.3
dB Note 1.
Pulsed CW compression measurement
dB (12 µsec pulse, 120 µsec period, 10%
duty cycle).
dB
± 0.8 ± 1.5
°
3.1
3.7
nanosec
Includes delay of test fixture (~0.6
nanosec.).
-49
-
dBc
Note 3. Refer to applications data for
performance with other protocols.
20.5
-
% Note 3.
42
-
%
27
30
Volts
Testing for conformance with RF
specifications is at +27 V.
-
+115
°C
Testing for conformance with RF
specification is at +25 °C.
-0.033
-
-
30
-
-
1.9
2.1
75
260
3.0
1.7
Class 1
Class M3
dB/°C
Watts
CW
dBc
°C/W
mA
mA
%
%
Bias quiescent currents held constant.
VSWR 10:1, all phase angles. No
degradation in output power before &
after test.
0<Pout<44.8 dBm CW, 3:1 VSWR
Theta jc is for output device. Verified
with IR scan. Note 2.
These DC quiescent currents are typical
of the levels that produce optimum
linearity for CDMA protocol.
Ratio of sense FET current, relative to RF
FET current. Ratios are: Stg 1: 33:1;
Stg 2: 58:1 Gates of sense & RF FETs
are DC connected. Measured with no RF
signal present.
a) 2000V, 100 pF, 1500 Ohms
b) 400V, 200 pF, zero Ohms
Mil STD 883E, Method 3015 for Human
Body Model and for Machine Model.
Page 2 of 15 Specifications subject to change without notice. US Patent No.6,822,321
http://www.cree.com/
Rev. 2

Share Link: 