DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

PBL386212QNT Просмотр технического описания (PDF) - Ericsson

Номер в каталоге
Компоненты Описание
производитель
PBL386212QNT
Ericsson
Ericsson  Ericsson
PBL386212QNT Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
PBL 386 21/2
15
16
}C3
C2
C1, C2 and C3 are digital inputs (internal pull-up) controlling the SLIC operating states.
Refer to section "Operating states" for details.
17
C1
18
DET
Detector output. Active low when indicating loop detection and ring trip, active high when indicating
ground key detection.
19
NC
No internal Connection.
20
VCC
+5 V power supply.
21
PLD
Programmable Loop Detector threshold. The loop detection threshold is programmed by a resistor
connected from this pin to AGND.
22
POV
Programmable Overhead Voltage. If pin is left open: The overhead voltage is internally set to min 1.0 V in
off-and on-hook. If a resistor is connected between this pin and AGND: the overhead voltage can be set
to higher values.
23
PLC
Prog. Line Current, the constant current part of the DC feed characteristic is programmed by a resistor
connected from this pin to AGND.
24
REF
A Reference, 49.9 k, resistor should be connected from this pin to AGND.
25
NC
No internal Connection.
26
RSN
Receive Summing Node. 200 times the AC-current flowing into this pin equals the metallic (transversal)
AC-current flowing from RINGX to TIPX. Programming networks for two-wire impedance and receive gain
connect to the receive summing node. A resistor should be connected from this pin to AGND.
27
AGND Analog Ground, should be tied together with BGND.
28
VTX
Transmit vf output. The AC voltage difference between TIPX and RINGX, the AC metallic voltage, is
reproduced as an unbalanced GND referenced signal at VTX with a gain of one (or one half, see pin
PTG). The two-wire impedance programming network connects between VTX and RSN.
SLIC Operating States
State C3
C2
C1
0
0
0
0
1
0
0
1
2
0
1
0
3
0
1
1
4
1
0
0
5
1
0
1
6
1
1
0
7
1
1
1
Table 1. SLIC operating states.
SLIC operating state
Open circuit
Ringing state
Active state
Not applicable
Not applicable
Active state
Active reverse
Active reverse
Active detector
-
Ring trip detector (active low)
Loop detector (active low)
-
-
Ground key detector (active high)
Loop detector (active low)
Ground key detector (active high)
9

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]