DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

NE56605-42 Просмотр технического описания (PDF) - Philips Electronics

Номер в каталоге
Компоненты Описание
производитель
NE56605-42
Philips
Philips Electronics Philips
NE56605-42 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Philips Semiconductors
System reset with built-in watchdog timer
Product data
NE56605-42
AC ELECTRICAL CHARACTERISTICS
Characteristics measured with VCC = 5.0 V, and Tamb = 25 °C, unless otherwise specified.
See Figure 24 (Test circuit 2) for test configuration used for AC parameters.
SYMBOL
PARAMETER
CONDITIONS
MIN. TYP. MAX. UNIT
tP1
Minimum power supply pulse width for
4.0 V negative-going VCC pulse 5.0 V
8.0
µs
detection
tCLKW
Clock input pulse width
3.0
µs
tCLK
Clock input cycle
20
µs
tWDM
Watchdog monitoring time (Notes 1, 6)
CT = 0.1 µF; RCT = open
5.0
10
15
ms
tWDR
Watchdog reset time (Notes 2, 6)
CT = 0.1 µF
1.0
2.0
3.0
ms
tPR
Power-on reset delay time (Notes 3, 6)
VCC = rising from 0 V; CT = 0.1 µF
50
100
150
ms
tPD1
RESET, RESET propagation delay time
RESET: RL1 = 2.2 k; CL1 = 100 pF
(Note 4)
tPD2
RESET: RL2 = 10 k; CL2 = 20 pF
2.0
10
µs
3.0
10
µs
tR1
RESET, RESET rise time (Note 5)
RESET: RL1 = 2.2 k; CL1 = 100 pF
1.0
1.5
µs
tR2
RESET: RL2 = 10 k; CL2 = 20 pF
1.0
1.5
µs
tF1
RESET, RESET fall time (Note 5)
RESET: RL1 = 2.2 k; CL1 = 100 pF
0.1
0.5
µs
tF2
RESET: RL2 = 10 k; CL2 = 20 pF
0.5
1.0
µs
NOTES:
1. ‘Watchdog monitoring time’ is the duration from the last pulse (negative-going edge) of the timer clear clock pulse until reset output pulse
occurs (see Figure 18). A reset signal is output if a clock pulse is not input during this time.
2. ‘Watchdog reset time’ is the reset pulse width (see Figure 18).
3. ‘Power-on reset delay time’ is the duration measured from the time VCC exceeds the upper detection threshold (VSH) and power-on reset
release is experienced (RESET output HIGH; RESET output LOW).
4. ‘RESET, RESET propagation delay time’ is the duration from when the supply voltage sags below the lower detection threshold (VSL) and
reset occurs (RESET output LOW, RESET output HIGH).
5. RESET, RESET rise and fall times are measured at 10% and 90% output levels.
6. Watchdog monitoring time (tWDM), watchdog reset time (tWDR), and power-on reset delay time (tPR) during power-on can be modified by
varying the CT capacitance. The times can be approximated by applying the following formula. The recommended range for CT is 0.001 µF
to 10 µF.
Formula 1.
Calculation for approximate tPR, tWDM, and tWDR values:
tPR (ms) 1000 × CT (µF)
tWDM (ms) 100 × CT (µF)
tWDR (ms) 20 × CT (µF)
Example:
When CT = 0.1 µF and WDC = open:
tPR 100 ms
tWDM 10 ms
tWDR 2.0 ms
2001 Aug 22
5

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]