DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX6826 Просмотр технического описания (PDF) - Maxim Integrated

Номер в каталоге
Компоненты Описание
производитель
MAX6826 Datasheet PDF : 13 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MAX6826-MAX6831
Dual Ultra-Low-Voltage SOT23 µP Supervisors with
Manual Reset and Watchdog Timer
Typical Operating Characteristics (continued)
(TA = +25°C, unless otherwise noted.)
VOLTAGE OUTPUT LOW vs. ISINK
0.350
VCC = +2.9V
0.300
0.250
0.200
0.150
0.010
0.005
0
01234567
ISINK (mA)
VOLTAGE OUTPUT HIGH vs. ISOURCE
2.92
VCC = +2.9V
2.90
2.88
2.86
2.84
2.82
2.80
2.78
2.76
2.74
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
ISOURCE (mA)
Pin Description
PIN
MAX MAX MAX MAX MAX MAX
6826 6827 6828 6829 6830 6831
NAME
FUNCTION
Active-Low Open-Drain or Push-Pull Reset Output. RESET changes from high
to low when VCC1, VCC2, or RESET IN input drops below the selected reset
1
1
1
1 RESET threshold, MR is pulled low, or the watchdog triggers a reset. RESET remains
low for the reset timeout period after all voltages exceed the device reset
threshold, MR goes low to high, or the watchdog triggers a reset.
Active-High Push-Pull Reset Output. RESET changes from low to high when
VCC1, VCC2, or RESET IN input drops below the selected reset threshold, MR
1
1
RESET is pulled low, or the watchdog triggers a reset. RESET remains HIGH for the
reset timeout period after all voltages exceed the device reset threshold, MR
goes low to high, or the watchdog triggers a reset.
2
2
2
2
2
2 GND Ground
Manual-Reset Input, Active-Low, Internal 50kW pullup to VCC. Pull low to force a
3
3
3
3
3
3
MR reset. Reset remains active as long as MR is low and for the reset timeout period
after MR goes high. Leave unconnected or connect to VCC, if unused.
Watchdog Input. If WDI remains high or low for longer than the watchdog timeout
period, the internal watchdog timer runs out and a reset is triggered for the reset
4
4
4
4
4
4
WDI
timeout period. The internal watchdog timer clears whenever reset is asserted,
the manual reset is asserted, or WDI sees a rising or falling edge. If WDI is left
unconnected or is connected to a three-stated buffer output, the watchdog feature
is disabled.