DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX6639(2005) Просмотр технического описания (PDF) - Maxim Integrated

Номер в каталоге
Компоненты Описание
производитель
MAX6639 Datasheet PDF : 22 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
2-Channel Temperature Monitor with Dual,
Automatic, PWM Fan-Speed Controller
Block Diagram
Detailed Description
VCC
MAX6639
DXP1
DXN
DXP2
TEMPERATURE
PROCESSING
BLOCK
PWM
GENERATOR
BLOCK
PWM1
PWM2
The MAX6639 monitors its own temperature and a
remote-diode-connected transistor or the temperatures
of two external-diode-connected transistors, which typi-
cally reside on the die of a CPU or other integrated cir-
cuit. The 2-wire serial interface accepts standard
SMBus write byte, read byte, send byte, and receive
byte commands to read the temperature data and pro-
gram the alarm thresholds. Temperature data can be
read at any time over the SMBus, and a programmable
alarm output can be used to generate interrupts, throt-
tle signals, or overtemperature shutdown signals.
ADD
SMBus
INTERFACE AND
SDA
REGISTERS
LOGIC
OT
THERM
FANFAIL
ALERT
The temperature data is also used by the internal dual-
PWM fan-speed controller to adjust the speed of up to
two cooling fans, thereby minimizing noise when the
system is running cool, but providing maximum cooling
when power dissipation increases. RPM feedback
allows the MAX6639 to control the fan’s actual speed.
SCL
TACH1
TACH2
GND
Write Byte Format
S
ADDRESS
WR
ACK
COMMAND
ACK
DATA
ACK
P
7 bits
Slave Address: equiva-
lent to chip-select line of
a 3-wire interface
Read Byte Format
8 bits
Command Byte: selects which
register you are writing to
8 bits
1
Data Byte: data goes into the register
set by the command byte (to set
thresholds, configuration masks, and
sampling rate)
S ADDRESS WR ACK COMMAND ACK
S ADDRESS RD ACK DATA
///
P
7 bits
Slave Address: equiva-
lent to chip-select line
8 bits
Command Byte: selects
which register you are
reading from
7 bits
Slave Address: repeated
due to change in data-
flow direction
8 bits
Data Byte: reads from
the register set by the
command byte
Send Byte Format
Receive Byte Format
S ADDRESS WR ACK COMMAND ACK P
S
7 bits
8 bits
Command Byte: sends com-
mand with no data, usually
used for one-shot command
S = START CONDITION
P = STOP CONDITION
SHADED = SLAVE TRANSMISSION
/// = NOT ACKNOWLEDGED
ADDRESS RD ACK DATA ///
P
7 bits
8 bits
Data Byte: reads data from
the register commanded
by the last read byte or
write byte transmission;
also used for SMBus alert
response return address
Figure 1. SMBus Protocols
6 _______________________________________________________________________________________