2-Channel Temperature Monitor with Dual,
Automatic, PWM Fan-Speed Controller
Table 4. Register Map (continued)
READ/
WRITE
REGISTER
NO.
POR
STATE
FUNCTION
D7
D6
ADDRESS
W
26h
0011 Fan 1 target
1100 duty cycle
MSB
R
27h
0000 Fan 2 current
0000 duty cycle
MSB
W
27h
0011 Fan 2 target
1100 duty cycle
MSB
Channel 1
R/W
28h
0100
000
minimum
fan-start
MSB
temperature
Channel 2
R/W
29h
0100
0000
minimum
fan-start
MSB
temperature
R
3Dh
0101 Read device
0
1
1000
ID
R
3Eh
0100
1101
Read
manufacturer
ID
0
1
R
3Fh
0000 Read device
0000 revision
0
0
Global Configuration Register (04h)
The global configuration register controls the shutdown
mode, power-on reset, SMBus timeout, and tempera-
ture channel 2 source select:
D7: Run/Standby. Normal operation is run (0).
Setting this bit to 1 suspends conversions and puts
the MAX6639 into low-power sleep mode.
D6: Software POR. Writing a 1 resets all registers to
their default values.
D5: SMBus Timeout Disable. Writing a zero
enables SMBus timeout for prevention of bus lockup.
When the timeout function is enabled, the SMBus
interface is reset if SDA or SCL remains low for more
than 74ms (typ).
D4: Temperature Channel 2 Source. Selects either
local or remote 2 as the source for temperature
channel 2 register data. Writing a zero to this bit
selects remote 2 for temperature channel 2.
D3: PWM Output Frequency Range. Selects either
the 20Hz to 100Hz range or the 5kHz to 25kHz range
for the PWM outputs (see Table 9).
D5
D4
D3
D2
D1
D0
LSB
LSB
LSB
LSB
LSB
0
1
1
0
0
0
0
0
1
1
0
1
0
0
0
0
0
0
Extended Temperature Registers (05h and 06h)
These registers contain the extended temperature data
from channels 1 and 2. Bits D[7:5] contain the 3 LSBs
of the temperature data. The bit values are 0.5°C,
0.25°C, and 0.125°C. When bit 0 is set to 1, a diode
fault has been detected.
Channel 1 and Channel 2 ALERT, OT, and THERM
Limits (08h Through 0Dh)
These registers contain the temperatures above which
the ALERT, THERM, and OT status bits set and outputs
assert (for the temperature channels that are not
masked). The data format is the same as that of the
channel 1 and channel 2 temperature registers: the
LSB weight is +1°C and the MSB is +128°C.