DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX6640(2004) Просмотр технического описания (PDF) - Maxim Integrated

Номер в каталоге
Компоненты Описание
производитель
MAX6640 Datasheet PDF : 22 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
2-Channel Temperature Monitor with Dual
Automatic PWM Fan-Speed Controller
Table 3. Register Map
REGISTER
READ/
WRITE
NO.
ADDRESS
POR
STATE
FUNCTION
D7
D6
D5
D4
D3
D2
D1
D0
R
00h
0000 Temperature MSB
0000 channel 1 (+128°C)
LSB
( 1° C )
R
01h
0000 Temperature MSB
0000 channel 2 (+128°C)
LSB
( 1° C )
R
02h
0000
0000
Status byte
Channel 1
ALERT
Channel 2
ALERT
Channel 1
OT
Channel 2
OT
Channel 1
THERM
Channel 2
THERM
Fan 1 fault
Fan 2
fault
R/W
03h
0000
0011
Output mask
Channel 1
ALERT
Channel 2
ALERT
Channel 1
OT
Channel 2
OT
Channel 1
THERM
Channel 2
THERM
Fan 1 fault
Fan 2
fault
SMBus Temp
Run
timeout channel 2
R/W
04h
0011
0000
Global
configuration
0 = run,
1= stby
POR
1 = reset
0=
enabled,
source:
1 = local,
Reserved Reserved Reserved Reserved
1 = 0 = remote
disabled
2
R
05h
0000
0000
Channel 1
extended
temperature
MSB
(0.5°C)
LSB Reserved Reserved Reserved Reserved Diode
(0.125°C)
fault
R
06h
0000
0000
Channel 2
extended
MSB
(0.5°C)
LSB
(0.125°C)
Reserved
Reserved
Reserved
Reserved
Diode
fault
temperature
R/W
08h
0101 Channel 1
0101 ALERT limit
MSB
LSB
( 1° C )
R/W
09h
0101 Channel 2
0101 ALERT limit
MSB
LSB
( 1° C )
R/W
0Ah
0110 Channel 1 OT
1110
limit
MSB
LSB
( 1° C )
0110 Channel 2 OT
LSB
R/W
0Bh
1110
limit
MSB
( 1° C )
R/W
0Ch
0101 Channel 1
0101 THERM limit
MSB
LSB
( 1° C )
R/W
0Dh
0101 Channel 2
0101 THERM limit
MSB
LSB
( 1° C )
R/W
10h
1000
0010
Fan 1
configuration
1
PWM
mode
Step-size
delay
(MSB)
Step-size
delay
Step-size
delay
(LSB)
Fan 1 Fan 1
channel 1 channel 2
control control
RPM
range
select
RPM
range
select
Minimum
R/W
11h
0000
0000
Fan 1
Configuration
2a
RPM step-
size A
(MSB)
RPM step-
size A
RPM step-
size A
RPM step-
size A
(LSB)
Temp
step-size
A (MSB)
Temp
step-size
A (LSB)
PWM
100% duty
cycle
fan
speed
0 = 0%,
1= value
______________________________________________________________________________________ 11