One-Time Programmable, Linear-Taper
Digital Potentiometers
VDD
tUP
CS
tCU
tCI
tIL
tIH
tIC
U/D
tIW
VW
Figure 2. Increment Mode Serial Interface Timing Diagram
VDD
tUP
CS
tCU
tCI
tIH
tIL
tIC
U/D
tIW
VW
Figure 3. Decrement Mode Serial Interface Timing Diagram
The value of the counter is then stored and the wiper
position is maintained.
The wiper performs a make-before-break transition,
ensuring that there is never an open circuit during a tran-
sition from one resistor tap to another. When the wiper is
at either end (max/min) of the resistor array, additional
transitions in the direction of the endpoint do not change
the counter value (the counter does not wrap around).
One-Time Programming
The factory-set default position of the wiper on power-
up is tap 16. However, the power-up position can be
changed once using the one-time programming fea-
ture. After the wiper is moved to the desired position,
the programming sequence is initiated by setting U/D
high, applying 11V to VPP, and then taking CS low. Five
pulses on CS (consisting of CS starting from low and
going high for tCH and then low for tCL) program the
device (Figure 4). The programming voltage should
then be taken to zero. After the device is programmed,
VPP can be set to zero or be allowed to float. The wiper
position is still adjustable, but always returns to this
programmed position on power-up.
If the intent is to program the device to a specific wiper
position and not to allow further adjustments, then six
programming pulses are required (as opposed to five),
as shown in Figure 4. The sixth pulse locks the wiper
position and disables the serial interface. This also
allows U/D and CS to float without any increase in sup-
ply current. Once the lockout bit is set, no further
adjustment to the potentiometer is possible, effectively
changing the potentiometer into a fixed resistor-divider
(Table 1).
Table 1. One-Time Programming Options
MODE
Factory Default
(Unprogrammed)
POWER-ON
RESET WIPER
POSITION
Tap 16
ADJUSTABLE
WIPER
Yes
Programmed
(5 Programming Pulses)
Programmed
position
Yes
Lock-Bit Set
(6 Programming Pulses)
Programmed
position
No
6 _______________________________________________________________________________________