Remote Temperature Sensor
with SMBus Serial Interface
Write Byte Format
S
ADDRESS
WR
7 bits
Slave Address: equiva-
lent to chip-select line of
a 3-wire interface
ACK
COMMAND
ACK
8 bits
Command Byte: selects which
register you are writing to
DATA
ACK
P
8 bits
Data Byte: data goes into the register
set by the command byte (to set
thresholds, configuration masks, and
sampling rate)
Read Byte Format
S ADDRESS WR ACK COMMAND ACK
S ADDRESS RD ACK DATA
A
P
7 bits
8 bits
7 bits
8 bits
Slave Address: equiva-
lent to chip-select line of
a 3-wire interface
Command Byte: selects
which register you are
reading from
Slave Address: repeated
due to change in data-
flow direction
Data Byte: reads from
the register set by the
command byte
Send Byte Format
S ADDRESS WR ACK
DATA
ACK P
7 bits
8 bits
S = Start condition
P = Stop condition
Data Byte: writes data to the
register commanded by the
last Read Byte or Write Byte
transmission
Shaded = Slave transmission
A = Not acknowledged
Figure 2. SMBus Protocols
Receive Byte Format
S ADDRESS WR
7 bits
ACK DATA A
P
8 bits
Data Byte: reads data from
the register commanded
by the last Read Byte or
Write Byte transmission;
also used for SMBus Alert
Response return address
+3V TO +5.5V
SMBUS
SERIAL
INTERFACE
(TO HOST)
2N3904
+12V
STBY VCC
MAX1618
SMBCLK
SMBDATA
DXP
DXN
ADD0
ALERT
ADD1
GND
Figure 3. Fan Control Application
and does not go inactive until the temperature drops
below TLOW.
Enable thermostat mode through the configuration reg-
ister (Table 4), with one bit to enable the feature and
another bit to set the output polarity (active high or
active low). The ALERT thermostat comparison is made
after each conversion, or at the end of any SMBus
transaction. For example, if the limit is changed while
the device is in standby mode, the ALERT output
responds correctly according to the last valid A/D
result. Upon entering thermostat mode, the ALERT out-
put is reset so that if the temperature is in the hysteresis
band ALERT initially goes inactive. The power-on reset
(POR) state disables thermostat mode.
Diode Fault Alarm
A continuity fault detector at DXP detects whether the
remote diode has an open-circuit condition, short-cir-
cuit to GND, or short-circuit DXP-to-DXN condition. At
the beginning of each conversion, the diode fault is
checked, and the status byte is updated. This fault
detector is a simple voltage detector; if DXP rises
_______________________________________________________________________________________ 9