M40Z111, M40Z111W
Table 5B. DC Characteristics for M40Z111W
(TA = 0 to 70°C; VCC = 3V to 3.6V or 2.7V to 3.3V)
Symbol
Parameter
ILI (1)
ILO (1)
Input Leakage Current
Output Leakage Current
Test Condition
Min
0V ≤ VIN ≤ VCC
0V ≤ VOUT ≤ VCC
ICC
Supply Current
Outputs open
VIL
Input Low Voltage
–0.3
VIH
Input High Voltage
2.0
VOL
Output Low Voltage
IOL = 4.0mA
VOH
Output High Voltage
IOH = –2.0mA
2.4
VOHB VOH Battery Back-up
IOUT2 = 1.0µA
2.0
IOUT1 VOUT Current (Active)
VOUT > VCC –0.3
VOUT > VCC –0.2
IOUT2 VOUT Current (Battery Back-up)
VOUT > VBAT –0.3
ICCDR Data Retention Mode Current
THS Threshold Select Voltage
VSS
Power-fail Deselect Voltage (THS = 0)
2.8
VPFD
Power-fail Deselect Voltage (THS = 1)
2.5
VSO
Battery Back-up Switchover Voltage
Note: 1. Outputs deselected.
Typ
Max
Unit
±1
µA
±1
µA
2
4
mA
0.8
V
VCC + 0.3 V
0.4
V
V
2.9
3.6
V
100
mA
65
mA
100
µA
150
nA
VOUT
V
2.9
3.0
V
2.6
2.7
V
2.5
V
6/12