DMS-30DR Series
SUNLIGHT READABLE, AUTO-DIMMING LED DISPL AY METERS
APPLICATIONS
Example: For a meter with a 2V full scale input (1.999 full
scale reading) and a desired display reading of
"1000" (with an input of 20mA), VFsr = 1.000 Volts
RShunt = 1.000V/(0.020 – 0.004)A
RShunt = 1.000V/0.016A = 62.5 Ohms
To calibrate the circuit of Figure 7, perform the following:
1. With 4mA applied, adjust the 50kpotentiometer (R2) to
display a reading of "000" (assuming that is the desired
reading).
2. With 20mA applied, adjust the gain-adjust potentiometer on
the back of the meter to display a reading of "1000". For
different full scale readings, alter the value of RShunt accordingly.
������ ��
��
���������
��
��������
��
���������
��
���
����������
�������
������
���
������
������
������
��������� ����������
������������������
Figure 7. 4-to-20mA Current Loop Operation
6. Digital Ammeter: Digital ammeters are finding ever-increasing usage
because analog-style ammeters (moving-vane types) now cost roughly
the same as their digital counterparts. Additionally, analog ammeters
are not nearly as rugged as modern digital panel voltmeters. Figure 9
illustrates a typical ammeter application. The circuit uses a ±200mV
input meter — the preferred range for most ammeters — to measure
the voltage developed across a 0.1current shunt. The circuit shown
represents a basic ammeter connection diagram. A detailed application
note describing digital dc ammeters is available at www.cd4power.com.
�������
����
������
����������
���
��
���������
��
���������
����������������������
������
����
�����
����
���������
�������
������
Figure 8. Basic DC Ammeter Circuit
7. External Gain Adjustment: Connect REFERENCE OUT
(pin 8) to REFERENCE IN (pin 7) for normal, factory calibrated,
operation. Use the +1.225V REFERENCE OUT (pin 9) for applica-
tions needing external gain adjustment. Figure 10 shows the wiring
configuration for each model. Calibration is performed with a precise,
near-full-scale, input voltage.
���
�������
����������
���
��
���������
������
��
���������
��
��������
��������
��
������ ����������
���������
��
��������������
��
���������
��������������
�����������
��������� �����
����������������
�����������
����������
������
Figure 9. External Gain Adjustment