Characteristics
Contact resistance
100 mΩ max.
Operate time
10 ms max.
Release time
5 ms max.
Bounce Time
Operate: Approx. 0.6ms
Release: Approx. 7.2ms
Max. switching frequency
Mechanical:
Electrical:
18,000 operations/hr
1,800 operations/hr at rated load
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
1,500 VAC (for suffix -G) 50/60Hz for 1 min between contacts of same polarity
Impulse withstand voltage
4,500 V (1.2 x 50 μs) between coil and contacts
Insulation
Distance
Creepage (Typ) 3.3 mm
Clearance (Typ) 2.7 mm
Tracking Resistance (CTI)
250 V
Vibration resistance
Destruction:
Malfunction:
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction:
Malfunction:
1,000 m/s2
100 m/s2
Endurance
Mechanical:
Electrical:
10,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr) for standard type
36,000 operations min. (10A at 250VAC)
100,000 operations min. (at 1,800 operations/hr), 12A 250 VAC) - applicable for
G5LE-1-E,NO contact only
Ambient temperature
Operating: 40°C to 85°C (with no icing)
Ambient humidity
Operating: 5% to 85%
Weight
Approx. 12 g
Approved Standards
UL Recognized (File No. E41643)
CSA Certified (File No. LR34815)
Model
G5LE
Coil rating
3 to 48 VDC
(Standard)
5 to 24 VDC
(-E versions)
9 to 24 VDC
(-G versions)
Contact rating
10 A, 250 VAC (general use), 6,000 cycles, 40°C (excluding -G type)
10 A, 125 VAC (general use), 100,000 cycles, 40°C (excluding -E, -G types)
8 A, 30 VDC (resistive load), 6,000 cycles, 40°C (excluding -E, -G types)
125 VA, 125 VAC, pilot duty, 100,000 cycles, 105°C (excluding -G type)
NO:
13 A, 120 VAC, resistive, 100,000 cycles, 85°C (AgSnO2 & -E types, only)
1/2 hp, 125 VAC, 100,000 cycles, 40°C (excluding -G type)
1/3 hp, 125 VAC, 30,000 cycles, 70°C (AgSnO2 type only, excluding -E, -G types)
400W-T (3.3A), 120 VAC, tungsten, 100,000 cycles (AgSnO2 type only, excluding -E, -G types)
TV-5, 120 VAC, 40°C (-ASI type only, excluding -E, -G types)
12 A, 250 VAC, general use, 100,000 cycles, 1s=on, 1s=off, 105°C (-E type only)
TV-8,120 VAC, 25,000 cycles, 40°C (-E type only)
10 A, 35 VDC, resistive, 100,000 cycles, 1s=on, 1s=off, 40°C (-G type only)
NC:
12 A, 250 VAC, general use, 30,000 cycles, 1s=on, 9s=off, 40°C (-E type only)
10 A, 35 VDC, resistive, 50,000 cycles, 5s=on, 5s=off, 40°C (-G type only)
1/8 hp, 120 VAC, 50,00 cycles, 40°C (AgSnO2 type only, excluding -E, -G types)
EN 61810-1, EN 60255, IEC (VDE TUV Reg No. R9151267, VDE Reg No. 6850UG)
G5LE
Model
Coil rating
Approx. 400 mW
3, 5, 6, 9, 12, 24, 48 VDC
Approx. 360 mW
5, 6, 12, 24, 48 VDC
Contact rating
10A, 250VAC (resistive load, 50,000 cycles at 85°C)
5A, 30VDC
2.5 A, 250 VAC (cosφ = 0.4)
PCB Relay G5LE 193