MC1658
ELECTRICAL CHARACTERISTICS (VEE = –5.2V, VCC = 0V [GND] )
–30°C
+25°C
Symbol
Characteristic
Min Max Min Max
IE
Power Supply Drain Current
–
–
–
32
IinH
VOH
VOL
Input Current
Output Voltage “Q” HIGH
Output Voltage “Q” LOW
–
–
–1.045 –0.875
–1.89 –1.65
–
–0.96
–1.85
350
–0.81
–1.62
+85°C
Min Max Unit
Condition
–
–
–0.89
–1.83
–
–
–0.7
–1.575
mAdc VIH to VCX Limit Applies for
1 or 2
µAdc VIH to VCX1
Vdc V3 to VCX. Limits Apply for 1
Vdc or 2
AC CHARACTERISTICS (VEE = –3.2V, VCC = +2.0V )
–30°C
+25°C
Symbol
t+
t–
Characteristic
Rise Time (10% to 90%)
Fall Time (10% to 90%)
Min Max Min Typ Max
–
2.7
–
1.6 2.7
–
2.7
–
1.4 2.7
fosc1
fosc2
Oscillator Frequency
130
–
130 155 175
–
–
78 100 120
TR3
Tuning Ratio Test
–
–
3.1 4.5
–
1 Germanium diode (0.4 drop) forward biased from 11 to 14 (11 14).
2 Germanium diode (0.4 drop) forward biased from 14 to 11 (11 14).
+ 3 TR = Output frequency at VCX GND
+ * Output frequency at VCX
2.0V
4 CX1 = 5.0pF connected from pin 11 to pin 14.
5 CX2 = 10pF connected from pin 11 to pin 14.
+85°C
Min Max
–
3.0
–
3.0
110
–
–
–
–
–
Condition
Unit
(See Figure 2)
ns VIHA to VCX, CX14 from Pin
ns 11 to Pin 14
MHz
–
VIHA to VCX, CX25 from
Pin 11 to Pin 14
CX25 from Pin 11 to Pin 14
VCC
+2.0Vdc
0.1µF
VCC1 1
0.01µF 12
Bias Filter
0.001µF 13
Input Filter
5 VCC2
0.1µF
6 Coax
Q
Channel “A”
Input 2
2
VCX
11
CX
CX
14
CX
8
Coaxial Cables
(Equal lengths, 50Ω)
To Scope
4 Coax
Q
Channel “B”
Input 2
Q
50%
Q
50%
90%
50%
10%
t–
t+
50%
90%
10%
t–
t+
50 ohm termination to ground located in each scope channel input.
All input and output cables to the scope are equal lengths of 50 ohm
coaxial cable. Wire length should be < 1/4 inch from TPin to input pin
and TPout to output pin.
Note: All power supply and logic levels are shown shifted 2.0V positive.
0.1µF
–3.2Vdc
VEE
Figure 2. AC Test Circuit and Waveforms
HIPERCOMM
3
BR1334 — Rev 4
MOTOROLA