Command Line Editing - The backspace
can be used to edit the command line.
Hitting the backspace key, or Control and H
simultaneously on some systems, erases
the previous character in the command line.
All of the characters can be erased except
for the "A" and "T." Register S5 allows the
user to select a character other than a
backspace to edit the command line.
Re-Execute Last Command - The A/
command causes the modem to re-execute
the last command line. This is the only
command which does not require the "AT"
prefix.
Ommitted Parameters - Most commands
include a parameter which determines the
command function. When this parameter is
omitted from the command string, it is
assumed to be a 0.
AT Command List
A - Answer Command -
Bn - Select Communications Standard
n=0 Selects CCITT standards
n=1 Selects Bell standards*
D - Dial Command -
L = Re-dial last number
P = Pulse dial
T = Tone dial
S=n = Dial stored number
W = Wait for dial tone
, = Pause for the duration ofr S8
@ = Wait for silence
! = Switch hook flash
; = Return to the command state
Escape Characters - A three character
escape sequence maybe entered while in
data mode to switch the modem into
command mode while remaining on line.
The escape character, set by Register S2,
must be entered 3 times in succession to
execute the escape. The default escape
sequence is "+++."
Result Codes - The modem issues a result
code after each action. Result codes may
be provided as full words, numeric codes or
may be disabled all together. Each result
code ends with a carriage return when
numeric result codes are chosen. When full
word result codes are chosen, a Line Feed
and Carriage Return precede and follow
each result code.
En - Command Echo
n=0 Do not echo commands
n=1 Enable command echo*
Hn - Switch Hook Control -
n=0 Switch hook relay opens*
n=1 The switch hook relay closes
In - Modem Identification
Ln - Speaker Volume -
n=0 Lowest speaker volume
n=1 Low speaker volume
n=2 Moderate speaker volume*
n=3 High speaker volume