DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

74F27 Просмотр технического описания (PDF) - Philips Electronics

Номер в каталоге
Компоненты Описание
производитель
74F27
Philips
Philips Electronics Philips
74F27 Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
Philips Semiconductors
Triple 3-input NOR gate
Product specification
74F27
DC ELECTRICAL CHARACTERISTICS
(Over recommended operating free-air temperature range unless otherwise noted.)
SYMBOL
PARAMETER
TEST CONDITIONS1
LIMITS
UNIT
MIN TYP2 MAX
VOH
High-level output voltage
VCC = MIN, VIL = MAX
±10%VCC
2.5
V
VIH = MIN, IOH = MAX
±5%VCC
2.7
3.4
V
VOL
Low-level output voltage
VCC = MIN, VIL = MAX
±10%VCC
0.30 0.50
V
VIH = MIN, IOl = MAX
±5%VCC
0.30 0.50
V
VIK
Input clamp voltage
VCC = MIN, II = IIK
-0.73 -1.2
V
II
Input current at maximum input voltage VCC = MAX, VI = 7.0V
100
µA
IIH
High–level input current
VCC = MAX, VI = 2.7V
20
µA
IIL
Low–level input current
VCC = MAX, VI = 0.5V
-0.6
mA
IOS
Short-circuit output current3
VCC = MAX
-60
-150
mA
ICC
Supply current (total)
ICCH VCC = MAX
VIN = GND
4.0
5.5
mA
ICCL VCC = MAX
VIN = 4.5V
8.5
12.0
mA
NOTES:
1 For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions for the applicable type.
2 All typical values are at VCC = 5V, Tamb = 25°C.
3 Not more than one output should be shorted at a time. For testing IOS, the use of high-speed test apparatus and/or sample-and-hold
techniques are preferable in order to minimize internal heating and more accurately reflect operational values. Otherwise, prolonged shorting
of a high output may raise the chip temperature well above normal and thereby cause invalid readings in other parameter tests. In any
sequence of parameter tests, IOS tests should be performed last.
AC ELECTRICAL CHARACTERISTICS
SYMBOL
PARAMETER
TEST
CONDITION
tPLH
tPHL
Propagation delay
Dna, Dnb, Dnc to Qn
Waveform 1
VCC = +5.0V
Tamb = +25°C
CL = 50pF, RL = 500
MIN TYP MAX
2.0
3.5
5.0
1.0
2.5
4.5
LIMITS
VCC = +5.0V ± 10%
Tamb = 0°C to +70°C
CL = 50pF, RL = 500
MIN
MAX
1.5
5.5
1.0
4.5
VCC = +5.0V ± 10%
Tamb = –40°C to +85°C
CL = 50pF, RL = 500
MIN
MAX
1.0
7.0
1.0
5.5
UNIT
ns
February 5, 1991
4

Share Link: 