DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

EVAL-AD7851CB(RevA) Просмотр технического описания (PDF) - Analog Devices

Номер в каталоге
Компоненты Описание
производитель
EVAL-AD7851CB
(Rev.:RevA)
ADI
Analog Devices ADI
EVAL-AD7851CB Datasheet PDF : 36 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
AD7851
STATUS REGISTER
The arrangement of the status register is shown below. The status register is a read-only register and contains 16 bits of data. The
status register is selected by first writing to the control register and putting two 1s in RDSLT1 and RDSLT0. The function of the
bits in the status register are described below. The power-up status of all bits is 0.
START
WRITE TO CONTROL REGISTER
SETTING RDSLT0 = RDSLT1 = 1
READ STATUS REGISTER
Figure 6. Flowchart for Reading the Status Register
MSB
ZERO
BUSY
ZERO
ZERO
ZERO
ZERO PMGT1 PMGT0
RDSLT1 RDSLT0 2/3 MODE
X
CALMD CALSLT1 CALSLT0 STCAL
LSB
Bit Mnemonic
15 ZERO
14 BUSY
13 ZERO
12 ZERO
11 ZERO
10 ZERO
9 PMGT1
8 PMGT0
7 ONE
6 ONE
5 2/3 MODE
4X
3 CALMD
2 CALSLT1
1 CALSLT0
0 STCAL
Status Register Bit Function Description
Comment
This bit is always 0.
Conversion/Calibration Busy Bit. When this bit is 1, this indicates that there is a conversion or calibration
in progress. When this bit is 0, there is no conversion or calibration in progress.
These four bits are always 0.
Power Management Bits. These bits along with the SLEEP pin will indicate if the part is in a power-down
mode or not. See Table VI in Power-Down Section for description.
Both these bits are always 1 indicating it is the status register that is being read. See Table II.
Interface Mode Select Bit. With this bit 0, the device is in Interface Mode 2. With this bit 1, the device is in
Interface Mode 1. This bit is reset to 0 after every read cycle.
Don’t care bit.
Calibration Mode Bit. A 0 in this bit indicates a self-calibration is selected, and a 1 in this bit indicates a
system calibration is selected (see Table III).
Calibration Selection Bits and Start Calibration Bit. The STCAL bit is read as a 1 if a calibration is in
progress and as a 0 if there is no calibration in progress. The CALSLT1 and CALSLT0 bits indicate
which of the calibration registers are addressed for reading and writing (see section on the Calibration
Registers for more details).