MYSON
TECHNOLOGY
MTL003
(Rev. 0.95)
¨ V/H SYNC Frequency Counter
MTL003 measures VSYNC/HSYNC frequency counted in the proper clock and using the following formulae:
fvsync = fosc / Nvsync 51/256
fhsync = fosc / Nhsync 58
Where
fvsync
fhsync
fosc
Nvsync
Nhsync
: VSYNC frequency
: HSYNC frequency
: oscillator clock with 14.31818 MHz
: counted number of VSYNC
: counted number of HSYNC
¨ V/H SYNC Presence Check
This function checks the input VSYNC, where Vpre flag is set when VSYNC is over 40Hz or cleared when
VSYNC is under 10Hz and the input is HSYNC, where Hpre flag is set when HSYNC is over 10KHz or
cleared when HSYNC is under 10Hz.
¨ V/H Polarity Detect
This function detects the input VSYNC/HSYNC high and low pulse duty cycle. If the high pulse duration is
longer than that of low pulse, the negative polarity is asserted; otherwise, positive polarity is asserted.
¨ Composite SYNC separation/insertion
MTL003 continuously monitors the input HSYNC. If the input VSYNC can be extracted from it, a CVpre flag is
set. MTL003 can insert HSYNC pulse during Composite VSYNC’s active time and the insertion frequency
can adapt to original HSYNC’s.
3.1.7 Auto Tune
Auto Tune function consists of Auto Position that automatically centering the screen and Auto Calibration
which contains Phase Calibration, Histogram, Min/Max Value, and Pixel Grab described as below. With this
auto adjustment support it is possible to measure the correct phase, frequency, gain, and offset of ADC. The
horizontal and vertical back porches of input image and the horizontal and vertical active regions can also be
measured. Firmware can adjust input image registers automatically by reading Auto Tune’s registers in single
or burst mode.
¨ Auto Position
MTL003 provides Horizontal/Vertical back porch and active region values. Users can use these values to set
input sample registers to aid in centering the screen automatically.
¨ Phase Calibration
MTL003 provides Auto Calibration registers to measure the quality of current ADC’s phase and frequency.
The biggest Auto Calibration registers value means the right value of ADC’s phase and frequency. MTL003
has two kinds of algorithms to calculate Auto Calibration’s value. One is the traditional Difference method, the
other is MYSON’s proprietary method; the latter one is recommended for a better performance.
¨ Histogram
Histogram means the total number of input pixels below/above one threshold value, for individual R/G/B
colors. This advanced function helps the firmware to analyze ADC performance. Usually the firmware can
use this information to measure ADC’s noise margin, and adjust its offset and gain, or even aid in the mode
detection.
¨ Min/Max Value
Min/Max value means minimum or maximum pixel value within the specified input active image region for
each RGB channel. This information is usually used to adjust ADC’s offset and gain.
¨ Pixel Grab
Pixel Grab means users can grab a single input pixel at any one point. The position of the point can be
programmed by users. This is another traditional method to measure ADC’s phase and frequency.