L9230
ELECTRICAL CHARACTERISTCS ( Tj = -40 to +150°C; VS = 5 to 28V) (continued)
Symbol
Parameter
Test Condition
Min. Typ. Max. Unit
Timing
f
PWM Frequency
min. operating time 10µs
2
30
kHz
fS Switching Frequency during
current limitation
5
30
kHz
tdon Output ON-delay
IN1 --> OUT1 or IN2 --> OUT2
3
5
µs
tdoff Output OFF-delay
3
5
µs
tr, tf Output rise-, fall Time
OUT1H--> OUT1L, OUT2H--> OUT2L, 0.2
0.4
1
µs
IOUT = 3 A
OUT1L--> OUT1H, OUT2L--> OUT2H
tddis Disable Delay Time
DIn --> OUTn, En --> OUTn
3
4
µs
tdp Power on Delay Time
VS = on --> output stage active
15
ms
Delay time for fault detection
5
15
µs
|∆I| Effect of reverse current at power 4,5V < VDMS < 5,5V
supply
- IVs < 3A
∆I for ISI, ISO, ISS, ISCK, IIN1, IIN2, IEN,IDI
(*) For lower pull up resistances than 27kΩ the specified value of xxxV (minimum) is guaranteed by design
100
µA
Note: 1. In case of SC OUTx to Vs the switch off current is always higher than the start value of current regulation (∆|IOUK| = |IOUK| - |IOUmax|
2. Guaranteed by design
3. Value is tested down to 6V. For supply voltage below 6V on increased current can be fed back in the device via a protection path
5/25