Physical layout of RSENSE resistor is critical to avoid the
possibility of false overcurrent occurrences. Ideally trace
routing between the RSENSE resistors and the HIP1015 and
HIP1016 is direct and as short as possible with zero current
in the sense lines. (See Figure 1.)
CORRECT
INCORRECT
TO ISEN AND
RISET
CURRENT
SENSE RESISTOR
FIGURE 1. SENSE RESISTOR PCB LAYOUT
Using the HIP1016 as a -48V Low Side Hot
Swap Power Controller
To supply the required VDD, it is necessary to maintain the
chip supply 12V above the -48V bus. This may be
accomplished with a +12V Regulator between the voltage
rail and pin 5 (VDD). By using a Regulator, the designer may
ignore the bus voltage variations. However, a low-cost
alternative is to use a Zener diode (See Figure 2 for typical
5A load control ) this option is detailed below.
Note that in this configuration the PGOOD feature (pin 7) is
not operational.
RCL
1.58k
1W
LOAD
0.001µF
HUF7554S3S
0.005
1%
1.47k
1%
2k
0.01µF
HIP1016
DD1
12V
0.047µF
VBUS
-48V
FIGURE 2.
NC
PWRON
Biasing the HIP1016
Table 3 gives typical component values for biasing the
HIP1016 in a 48V application. The formulas and calculations
deriving these values are also shown below.
TABLE 3. TYPICAL VALUES FOR A -48V HOT SWAP
APPLICATION
SYMBOL
PARAMETER
RCL
DD1
1.58k, 1W
12V Zener Diode, 50mA Reverse Current
When using the HIP1016 to control -48V, a Zener diode may
be used to provide the +12V bias to the chip. If a Zener is
used then a current limit resistor should also be used.
Several items must be taken into account when choosing
values for the current limit resistor (RCL) and Zener Diode
(DD1):
• The variation of the VBUS (in this case, -48V)
• The chip supply current needs for all functional conditions
• The power rating of RCL.
• The current rating of DD1
Formulas
1. Sizing RCL:
RCL = (VBUS,MIN - 12)/ICHIP
2. Power Rating of RCL:
PRCL = IC(VBUS,MAX - 12)
3. DD1 Current Rating:
IDD1 = (VBUS,MAX - 12)/RCL
Example:
A typical -48V supply may vary from -36 to -72V. Therefore,
VBUS,MAX = -72V
VBUS,MIN = -36V
ICHIP = 15mA (max)
Sizing RCL:
RCL = (VBUS,MIN - 12)/IC
RCL = (36 - 12)/0.015
RCL = 1.6k[Typical Value = 1.58k]
Power Rating of RCL:
PRCL = IC(VBUS,MAX - 12)
PRCL = (0.015)(72 - 12)
PRCL = 0.9W [Typical Value = 1W]
DD1 Current Rating:
IDD1 = (VBUS,MAX - 12)/RCL
IDD1 = (72 - 12)/1.58k
IDD1 = 38mA [Typical Value = 12V rating, 50mA reverse
current]