10. Reliability Test
Environment test conditions are listed as following table.
Items
Required Condition
Temperature Humidity Bias (THB) Ta= 50, 80%RH, 240hours
High Temperature Operation (HTO) Ta= 50, 50%RH , 240hours
Low Temperature Operation (LTO) Ta= 0, 240hours
High Temperature Storage (HTS) Ta= 60, 240hours
Low Temperature Storage (LTS) Ta= -20, 240hours
Doc No.: 400035745
Issued Date: 02,Oct, 2009
Model No.: M215H1-L03
Approval
Note
Vibration Test
(Non-operation)
Acceleration: 1.5 Grms
Wave: Half-sine
Frequency: 10 - 300 Hz
Sweep: 30 Minutes each Axis (X, Y, Z)
Shock Test
(Non-operation)
Thermal Shock Test (TST)
On/Off Test
ESD (Electro Static Discharge)
Acceleration: 50 G
Wave: Half-sine
Active Time: 11 ms
Direction : ± X, ± Y, ± Z.(one time for each Axis)
-20/30min , 60/ 30min , 100 cycles
25,On/10sec , Off /10sec , 30,000 cycles
Contact Discharge: ± 8KV, 150pF(330)
Air Discharge: ± 15KV, 150pF(330)
Altitude Test
Operation:10,000 ft / 24hours
Non-Operation:30,000 ft / 24hours
11. PRECAUTIONS
11.1 ASSEMBLY AND HANDLING PRECAUTIONS
(1) Do not apply rough force such as bending or twisting to the module during assembly.
(2) To assemble or install module into user’s system can be only in clean working areas. The dust and oil
may cause electrical short or worsen the polarizer.
(3) It’s not permitted to have pressure or impulse on the module because the LCD panel and Backlight
will be damaged.
(4) Always follow the correct power sequence when LCD module is connecting and operating. This can
prevent damage to the CMOS LSI chips during latch-up.
(5) Do not pull the I/F connector in or out while the module is operating.
(6) Do not disassemble the module.
(7) Use a soft dry cloth without chemicals for cleaning, because the surface of polarizer is very soft and
easily scratched.
(8) It is dangerous that moisture come into or contacted the LCD module, because moisture may damage
LCD module when it is operating.
(9) High temperature or humidity may reduce the performance of module. Please store LCD module
within the specified storage conditions.