DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

1EDI2004AS Просмотр технического описания (PDF) - Infineon Technologies

Номер в каталоге
Компоненты Описание
производитель
1EDI2004AS Datasheet PDF : 138 Pages
First Prev 31 32 33 34 35 36 37 38 39 40 Next Last
EiceDRIVERTM SIL
1EDI2004AS
Functional Description
2.4.5 Operating Modes
2.4.5.1 General Operation
At any time, the driver can be in one out of seven possible operating modes:
• OPM0: Default Mode (default after reset, device is disabled).
• OPM1: Error Mode (reached after Event Class B, device is disabled).
• OPM2: Configuration Mode (device is disabled, configuration of the device can be modified).
• OPM3: Configured Mode (device is configured and disabled).
• OPM4: Active Mode (normal operation).
• OPM5: Verification mode (intrusive diagnostic functions can be triggered).
• OPM6: Weak active mode (the device can be turned on but with restrictions)
The current active mode of the device is given by bit field SSTAT.OPM.
The concept of the device is based on the following general ideas:
• The driver can only switch the IGBT on when OPM4 mode is active (exception: weak-turn on in OPM6).
• Starting from Mode OPM0 or OPM1, the Active Mode OPM4 can only be activated through a dedicated SPI
command sequence and the activation of the hardware signal EN. As a result, the probability that the
device goes to OPM4 mode due to random signals is negligible.
• Differentiations of errors: different classes of errors are defined, leading to different behavior of the device.
The state diagram for the operating modes is given in Figure 11:
Event Class B
All Reset Events
Event Class B
Reset Event
Event Class B
Reset Event
OPM0
Default
CLRS set
OPM1
Error
Reset Event
Event Class A
Reset Event
„ENTER_CMODE“
„ENTER_VMODE“
OPM5
Verification
EN Valid Transition
OPM6
Weak Active
OPM2
Configuration
„ENTER_CMODE“
Event Class B
„EX IT _CMOD E“
OPM3
Configured
All Event Class B
Event Class B
Reset Event
Event Class A
EN Valid Transition
OPM4
Active
Event Class B
Reset Event
Figure 11 Operating Modes State Diagram