5.5.10 Insulation Characteristics
Table 61 Isolation Characteristics referring to DIN EN 60747-5-2 (VDE 0884 - 10):2006-12
Description
Symbol Characteristic
Installation classification per EN60664-1, Table 1:
rated main voltage less than 150 Vrms
rated main voltage less than 300 Vrms
rated main voltage less than 600 Vrms
Climatic Classification
I - IV
I - III
I - II
40 / 125 / 21
Pollution Degree (EN 60664-1)
2
Minimum External Clearance
CLR
8.12
Minimum External Creepage
CPG
8.24
Minimum Comparative Tracking Index
CTI
400
Maximum Repetitive Insulation Voltage
Highest Allowable Overvoltage1)
VIORM
VIOTM
1420
6000
Maximum Surge Insulation Voltage
VIOSM
6000
1) Refer to VDE 0884 for a detailed description of Method a and Method b partial discharge
Unit
mm
mm
VPEAK
VPEAK
VPEAK
Table 62 Isolation Characteristics referring to UL 1577
Description
Symbol Characteristic
Unit
Insulation Test Voltage / 1 min
VISO
3750
Vrms
Insulation Test Voltage / 1 sec
VISO
4500
Vrms