Table 30: Description of WaterLevelReg bits
Bit
Symbol
Description
7 to 6 -
Reserved for future use.
5 to 0
WaterLevel
This register defines a warning level to indicate a FIFO-buffer over- or
underflow:
The bit HiAlert in Status1Reg is set to logic 1, if the remaining
number of bytes in the FIFO-buffer space is equal or less than the
defined number of WaterLevel bytes.
The bit LoAlert in Status1Reg is set to logic 1, if equal or less than
WaterLevel bytes are in the FIFO.
Remark: For the calculation of HiAlert and LoAlert see Section 9.2.1.8
“Status1Reg”.
9.2.1.13 ControlReg
Miscellaneous control bits.
Table 31: ControlReg register (address 0Ch); reset value: 10h
Bit
7
6
5
4
3
2
1
0
Symbol TStopNow TStartNow
-
RxLastBits
Access
w
w
RFU
r
Rights
Table 32: Description of ControlReg bits
Bit Symbol
Description
7
TStopNow
Set to logic 1, the timer stops immediately.
Reading this bit will always return 0.
6
TStartNow
Set to logic 1 starts the timer immediately.
Reading this bit will always return 0.
5 to 3 -
Reserved for future use.
2 to 0 RxLastBits
Shows the number of valid bits in the last received byte. If 0, the
whole byte is valid.