DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

BTS711L1 Просмотр технического описания (PDF) - Infineon Technologies

Номер в каталоге
Компоненты Описание
производитель
BTS711L1
Infineon
Infineon Technologies Infineon
BTS711L1 Datasheet PDF : 18 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Smart High-Side Power Switch
BTS711L1
Parameter and Conditions, each of the four channels Symbol
at Tj = 25 °C, Vbb = 12 V unless otherwise specified
Values
Unit
min typ max
Standby current, all channels off
Tj =25°C:
VIN = 0
Tj =150°C:
Leakage output current (included in Ibb(off))
VIN = 0
Operating current 9), VIN = 5V, Tj =-40...+150°C
IGND = IGND1/2 + IGND3/4,
one channel on:
four channels on:
Ibb(off)
IL(off)
IGND
-- 28 60 µA
-- 44 70
--
-- 12 µA
--
2
3 mA
--
8 12
Protection Functions10)
Initial peak short circuit current limit, (see timing
diagrams, page 13)
each channel, Tj =-40°C: IL(SCp)
5.5 9.5 13 A
Tj =25°C:
Tj =+150°C:
4.5 7.5 11
2.5 4.5
7
two parallel channels
twice the current of one channel
four parallel channels four times the current of one channel
Repetitive short circuit current limit,
Tj = Tjt
each channel
two parallel channels
four parallel channels
IL(SCr)
--
4
-- A
--
4
--
--
4
--
(see timing diagrams, page 13)
Initial short circuit shutdown time
Tj,start =-40°C:
Tj,start = 25°C:
(see page 11 and timing diagrams on page 13)
Output clamp (inductive load switch off)11)
at VON(CL) = Vbb - VOUT
Thermal overload trip temperature
Thermal hysteresis
toff(SC)
VON(CL)
Tjt
Tjt
-- 48
--
29
-- 47
150
--
-- 10
-- ms
--
-- V
-- °C
-- K
Reverse Battery
Reverse battery voltage 12)
Drain-source diode voltage (Vout > Vbb)
IL = - 1.9 A, Tj = +150°C
-Vbb
-VON
--
--
-- 610
32 V
-- mV
9) Add IST, if IST > 0
10) Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are not
designed for continuous repetitive operation.
11) If channels are connected in parallel, output clamp is usually accomplished by the channel with the lowest
VON(CL)
12) Requires a 150 resistor in GND connection. The reverse load current through the intrinsic drain-source
diode has to be limited by the connected load. Note that the power dissipation is higher compared to normal
operating conditions due to the voltage drop across the intrinsic drain-source diode. The temperature
protection is not active during reverse current operation! Input and Status currents have to be limited (see
max. ratings page 3 and circuit page 8).
Data Sheet
6
Rev 1.2, 2010-03-16

Share Link: 