DBQ/DVQ Series
420W Digital Fully Regulated Intermediate
DC-DC Bus Converter
DBQ0135V2: 12V/35A FUNCTIONAL SPECIFICATIONS (VOLTAGE APPLIED TO SCL SDA SMBALERT AND ON/OFF 2, MIN: -0.3V MAX: 3.6V)
ABSOLUTE MAXIMUM RATINGS
Conditions
Minimum Typical/Nominal Maximum
Units
Input Voltage, Continuous
0
80
Vdc
Input Voltage, Transient
100 mS max. duration
100
Vdc
Isolation Voltage
Input to output
2250
Vdc
On/Off Remote Control
Power on, referred to -Vin
0
13.5
Vdc
Output Power
0
428.4
W
Output Current
Current-limited, no damage, short-circuit protected
0
35
A
SCL / SDA / SMBALERT / ON/OFF 2
-0.3
3.6
Vdc
Storage Temperature Range
Vin = Zero (no power)
-55
125
°C
Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those
listed in the Performance/Functional Specifications Table is not implied or recommended.
INPUT
Operating voltage range (V2)
36
48
75
Vdc
Start-up threshold
(Default, configurable via PMBus)
33
34
35
Vdc
Undervoltage shutdown
(Default, configurable via PMBus)
31
32
34
Vdc
Internal Filter Type
Pi
External Input fuse
20
A
Input current
Full Load Conditions
Vin = nominal
9.19
9.44
A
Low Line input current
Vin = minimum
12.25
12.59
A
Inrush Transient
Vin = 48V.
1.3
2.6
A2-Sec.
Short Circuit input current
0.05
0.1
A
No Load input current
Iout = minimum, unit=ON
75
112
mA
Shut-Down input currrent(Off, UV, OT)
20
30
mA
Back Ripple Current
20
40
mAp-p
GENERAL and SAFETY
Input to output
2250
Vdc
Isolation Voltage
Input to Baseplate
1500
Vdc
Output to Baseplate
1500
Vdc
Insulation Safety Rating
functional
Isolation Resistance
10
Isolation Capacitance
1500
pF
Safety
Calculated MTBF
Certified to UL-60950-1, CSA-C22.2 No.60950-1, IEC/
EN60950-1, 2nd edition
Yes
Per Telcordia SR-332, Issue 2, Method 1, Class 1, Ground Fixed,
Tcase=+25°C
1800
Hours x 103
DYNAMIC CHARACTERISTICS
Switching Frequency (Configurable via PMBus)
Fixed Frequency Control
175
KHz
Turn On Time (Default, Configurable via PMBus)
Vin On to Vout Regulated
60
mS
Remote On to Vout Regulated
25
mS
Vout Rise Time (Default, Configurable via PMBus)
From 0%~100%
20
mS
Vout Fall Time of Regulated Off (Default, Configurable via PMBus)
From 100%~0%
20
mS
Dynamic Load Response
50-75-50%, 0.1A/us,within 1% of Vout
200
300
μSec
Dynamic Load Peak Deviation
same as above
±300
±500
mV
www.murata-ps.com/support