B32560 ... B32564
General purpose (stacked) SilverCapTM
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k0" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V2/µs.
Note:
The values of dV/dt and k0 provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt values
Lead spacing
VR
VRMS
V DC V AC
63 40
100 63
250 160
400 200
420 200
630 350
630 400
1000 500
7.5 mm
dV/dt in V/µs
120
150
200
275
320
360
10 mm
60
75
150
175
320
15 mm
50
100
125
150
22.5 mm
27.5 mm
50
25
100
50
125
60
60
k0 values
Lead spacing 7.5 mm
VR
V DC
63
VRMS
V AC
40
k0 in V2/µs
15 000
100 63 30 000
250 160 100 000
400 200
420 200
630 350
630 400
220 000
400 000
1000 500 720 000
10 mm
7500
15 000
75 000
140 000
400 000
15 mm
10 000
50 000
100 000
190 000
22.5 mm
10 000
50 000
100 000
27.5 mm
5 000
25 000
50 000
50 000
Please read Cautions and warnings and
Important notes at the end of this document.
Page 13 of 32