B32560 ... B32564
General purpose (stacked) SilverCapTM
Technical data
Operating temperature range Max. operating temperature Top,max
125 °C
Upper category temperature Tmax
+125 °C
Lower category temperature Tmin
55 °C
Rated temperature TR
+85 °C
Dissipation factor tan δ (in 10-3) at
CR ≤ 0.1 µF 0.1 µF < CR ≤ 1 µF CR > 1 µF
at 20 °C
1 kHz 8
8
10
(upper limit values)
10 kHz 15
15
100 kHz 30
Insulation resistance Rins
or time constant τ = CR Rins
at 20 °C, rel. humidity ≤ 65%
VR
CR ≤ 0.33 µF
≤ 100 V DC 3750 MΩ
≥ 250 V DC 7500 MΩ
CR > 0.33 µF
1250 s
2500 s
(minimum as-delivered values)
DC test voltage
1.4 VR, 2 s
Category voltage VC
TA (°C)
DC voltage derating AC voltage derating
(continuous operation with VDC TA ≤ 85
VC = VR
VC,RMS = VRMS
or VAC at f ≤ 60 Hz)
85<TA≤125 VC = VR (165TA)/80 VC,RMS=VRMS (165TA)/80
Operating voltage Vop for
TA (°C)
DC voltage (max. hours) AC voltage (max. hours)
short operating periods
TA ≤ 100 Vop = 1.25 VC (2000 h) Vop = 1.0 VC,RMS (2000 h)
(VDC or VAC at f ≤ 60 Hz)
100<TA≤125 Vop = 1.25 VC (1000 h) Vop = 1.0 VC,RMS (1000 h)
Damp heat test
56 days1)/40 °C/93% relative humidity
Limit values after damp
heat test
Reliability:
Capacitance change ∆C/C
Dissipation factor change ∆ tan δ
Insulation resistance Rins
or time constant τ = CR Rins
≤ 5%
≤ 3 10-3 (at 1 kHz)
≤ 5 10-3 (at 10 kHz)
≥ 50% of minimum
as-delivered values
Failure rate λ
Service life tSL
1 fit (≤ 1 10-9 /h) at 0.5 VR, 40 °C
200 000 h at 1.0 VR, 85 °C
For conversion to other operating conditions and temperatures,
refer to chapter "Quality, 2 Reliability".
Failure criteria:
Total failure
Short circuit or open circuit
Failure due to variation
of parameters
Capacitance change ∆C/C
Dissipation factor tan δ
Insulation resistance Rins
or time constant τ = CR Rins
> 10%
> 2 upper limit value
< 150 MΩ (CR ≤ 0.33 µF)
< 50 s (CR > 0.33 µF)
1) Test criteria must be met after exposure to damp heat for 21 days
Please read Cautions and warnings and
Important notes at the end of this document.
Page 12 of 32